(1)

Background

Hormonal fluctuations across the menstrual cycle lead to multiple changes in physiological parameters such as body temperature, cardiovascular function, respiratory rate and perfusion. Electronic wearables analyzing those parameters might present a convenient alternative to urinary ovulation tests for predicting the fertile window. (2)

Methods

We conducted a prospective observational study including women aged 18-45 years without current hormonal therapy who used a wrist-worn medical device and urinary ovulation tests for a minimum of three cycles. We analyzed the accuracy of both the retrospective and prospective algorithms using a generalized linear mixed-effects model. The findings were compared to real-world data from bracelet users who also reported urinary ovulation tests. (3)

Results

A total of 61 study participants contributing 205 cycles and 6081 real-life cycles from 3268 bracelet users were included in the analysis. The mean error in identifying ovulation with the wrist-worn medical device retrospective algorithm in the clinical study was 0.31 days (95% CI -0.13 to 0.75). The retrospective algorithm identified 75.4% of fertile days, and the prospective algorithm identified 73.8% of fertile days correctly within the pre-specified equivalence limits (±2 days). The quality of the retrospective algorithm in the clinical study could be confirmed by real-world data. (4)

Conclusion

Our data indicate that wearable sensors may be used to accurately detect the periovulatory period.

Для цитирования: Niggli Angela, Rothenbühler Martina, Sachs Maike, Leeners Brigitte. Can Wrist-Worn Medical Devices Correctly Identify Ovulation?. Sensors (Basel, Switzerland). 2023. DOI: 10.3390/s23249730.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.