MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Acta ortopedica mexicana · 2022

[Reliability of radiographic parameters to determine the surgical success in distal radius fractures].

García-González N, Berumen-Nafarrate E, Ávila-Carrasco L, Martínez-Fierro M, Monárrez-Espino J

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

INTRODUCTION

distal radius fractures are the most common in upper extremities. Therefore, it is important to standardize radiographic measures for their surgical approach. This study assessed the intra/interobserver reproducibility of radiographic parameters associated with surgical success of distal radius fractures.

MATERIAL AND

METHODS

retrospective cross-sectional design of secondary data extracted from clinical records. Posteroanterior and lateral X-rays of 112 distal radius fractures were assessed by two trauma specialists standardized in the measurements required to compute five parameters indicative of postoperative success: radial height, radial inclination, volar tilt, ulnar variance, and articular stepoff. The reproducibility of distances and angles was evaluated using the Bland-Altman method, calculating the mean of the difference between measurements, the range at ± 2 SD, and the proportion of measurements outside ± 2 SD. Postoperative success was also compared between patients with and without obesity according to the mean of the two measures made by each evaluator.

RESULTS

evaluator 1 had the largest intra-observer difference in radial height (0.16 mm) and the largest proportion outside ± 2 SD in ulnar variance (8.1%); evaluator 2 had the largest difference in volar tilt (1.92o) and the highest proportion in radial inclination (10.7%). The largest inter-observer difference was for ulnar variance (1.02 mm) and the largest proportion outside ± 2 SD. for radial height (5.4%). Radial tilt had the largest difference (1.41o) with 4.5% of measurements outside ± 2 SD. Ulnar variance and volar tilt had the largest difference in postoperative success between evaluators, especially in patients with obesity.

CONCLUSION

improving the radiographic quality and standardizing the measurements results in more reproducible indicators.

Для цитирования: García-González N, Berumen-Nafarrate E, Ávila-Carrasco L, Martínez-Fierro M, Monárrez-Espino J. [Reliability of radiographic parameters to determine the surgical success in distal radius fractures].. Acta ortopedica mexicana. 2022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.