MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12880-015-0047-2

Медицинская библиотека · BMC medical imaging · 2015

A comparative study of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and (99m)Tc-MDP whole-body bone scanning for imaging osteolytic bone metastases.

Zhang Lin, Chen Lihua, Xie Qiao, Zhang Yongke, Cheng Lin, Li Haitao, Wang Jian

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The objective of this study was to evaluate the feasibility and diagnostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and (99m)Tc-methylenediphosphonate (MDP) whole-body bone scanning (BS) for the detection of osteolytic bone metastases.

METHODS

Thirty-four patients with pathologically confirmed malignancies and suspected osteolytic bone metastases underwent 18F-FDG PET/CT and (99m)Tc-MDP whole-body BS within 30 days. The sensitivity, specificity, and accuracy with respect to the diagnosis of osteolytic bone metastases and bone lesions were compared between the two imaging methods.

RESULTS

The sensitivity, specificity, and accuracy of 18F-FDG PET/CT for the diagnosis of osteolytic bone metastases were 94.3% (95% confidence interval [CI], 91.6-96.2%), 83.3% (95% CI, 43.6-96.9%), and 94.2% (95% CI, 91.5-96.1%), respectively. It was found that (99m)Tc-MDP whole-body BS could discriminate between patients with 50.2% (95% CI, 45.4-55.1%) sensitivity, 50.0% (95% CI, 18.8-81.2%) specificity, and 50.2% (95% CI, 45.5-55.1%) accuracy. 18F-FDG PET/CT achieved higher sensitivity, specificity, and accuracy in detecting osteolytic bone metastases than 99mTc-MDP whole-body BS (p<0.001).

CONCLUSIONS

F-FDG PET/CT has a higher diagnostic value than (99m)Tc-MDP whole-body BS in the detection of osteolytic bone metastases, especially in the vertebra.

Для цитирования: Zhang Lin, Chen Lihua, Xie Qiao, Zhang Yongke, Cheng Lin, Li Haitao, Wang Jian. A comparative study of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and (99m)Tc-MDP whole-body bone scanning for imaging osteolytic bone metastases.. BMC medical imaging. 2015. DOI: 10.1186/s12880-015-0047-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.