MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-023-04438-5

Медицинская библиотека · Journal of orthopaedic surgery and research · 2023

Association between imaging parameter changes and triangular fibrocartilage complex injury after distal radius fractures.

Tan Chunye, Wang Zeyu, Li Linwei

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Triangular fibrocartilage complex (TFCC) injury is a frequent soft tissue injury that has been observed to accompany distal radius fractures (DRFs) with concomitant changes in radiologic parameters. The aim of this study was to investigate the relevance of distal radial radiologic parameters associated with DRF and traumatic TFCC injury.

METHODS

A total of 172 patients with distal radius fractures who underwent X-ray, CT, and MRI before undergoing volar locking plate or external splint fixation between October 2021 and December 2022 were included in this study. An analysis of various radiologic parameters and the classification of fracture type and TFCC injuries by CT and MRI was performed. All patients were divided into the TFCC uninjured group and the injured group. The incidence and relevant radiologic parameters were compared.

RESULTS

This study included 76 males and 96 females with a mean age of 56.1 years. Among all patients, 33 (19.2%), 40 (23.2%), and 99 (57.6%) had DRF with A, B, and C fractures, respectively, according to the AO/OTA classification. In patients with fractures, the TFCC was found to be injured in 54.1% (93/172) of patients (type 1A in 21, 1B in 46, 1C in 39, and 1D in 35) but uninjured in 45.9% (79/172). There were significant differences between the TFCC injured and uninjured groups regarding the radius length (p = 0.044) and DRUJ distance (p = 0.040) of radiologic parameters that changed with DRF, although there were no differences between the two groups regarding gender, age, injured side, intra- and extra-articular, radius inclination and palmer tilt angle, or sagittal translation. Within the TFCC injured group, the radius length and DRUJ distance were 4.83 mm and 2.95 mm less or wider than 7.19 mm and 1.83 mm of the uninjured group. Moreover, shorter radius length was related to type lB TFCC injury (p = 0.041). Both radius length (AUC = 0.658) and DRUJ distance (AUC = 0.582) had no convincing predictive value for TFCC injury in DRF.

CONCLUSION

1B TFCC injury is most common in patients with DRF and concomitant TFCC injury. Both radius length and DRUJ distance have a significant statistical correlation with TFCC injury, and patients with TFCC injury tend to have a shortened radius and wider DRUJ distance, although they have no predictive value for TFCC injury in DRF. In addition, a shorter radius length was related to type lB TFCC injury.

Для цитирования: Tan Chunye, Wang Zeyu, Li Linwei. Association between imaging parameter changes and triangular fibrocartilage complex injury after distal radius fractures.. Journal of orthopaedic surgery and research. 2023. DOI: 10.1186/s13018-023-04438-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.