OBJECTIVE

To examine the stability of plate (locking and non-) versus screw constructs in the fixation of these fractures.

METHODS

An anteromedial coronoid facet fracture (OTA/AO type 21-B1, O'Driscoll type 2, subtype 3) was simulated in 24 synthetic ulna bones that were then assigned to 3 fracture fixation groups: non-locking plate, locking plate (LP), or screw fixation. Each construct was first cycled in tension (through a simulated medial collateral ligament) and then in compression. They were then loaded to failure (displacement >2 mm). Fracture fragment displacement was recorded with an optical tracking system.

RESULTS

During tension testing, a mean maximum fragment displacement of 12 ± 13 and 14 ± 9 μm was seen in the locking and non-locking constructs, respectively. There was no difference in fragment motion between the plated constructs. All screw-only fixed constructs failed during the tension protocol. During compression testing, the mean maximum fragment displacement for the screw-only construct (64 ± 79 μm) was significantly greater than locking (9 ± 5 μm) and non-locking constructs (10 ± 9 μm). During load to failure testing, the maximum load to failure in the screw-only group (316 ± 83 N) was significantly lower than locking (650.4 ± 107 N) and non-locking constructs (550 ± 76 N). There was no difference in load to failure between the plated groups.

CONCLUSION

Fixation of anteromedial coronoid fractures (type 2, subtype 3) is best achieved with a plating technique. Although LPs had greater stiffness, they did not offer any advantage over conventional non-LPs with respect to fracture fragment displacement in this study.

CLINICAL RELEVANCE: Isolated screw fixation showed inferior stability when compared with plate constructs for these fractures. This could result in loss of fracture reduction leading to instability and posttraumatic arthrosis.

Для цитирования: Morellato John, Louati Hakim, Desloges William, Papp Steven, Pollock J Whitcomb. Fixation of Anteromedial Coronoid Facet Fractures: A Biomechanical Evaluation of Plated Versus Screw Constructs.. Journal of orthopaedic trauma. 2018. DOI: 10.1097/bot.0000000000001266.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.