Comparison of wear and fracture resistance of additively and subtractively manufactured screw-retained, implant-supported crowns.

Diken Türksayar Almira Ada, Demirel Münir, Donmez Mustafa Borga, Olcay Emin Orkun, Eyüboğlu Tan Fırat, Özcan Mutlu

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: Additively manufactured resins indicated for fixed definitive prostheses have been recently marketed. However, knowledge on their wear and fracture resistance when fabricated as screw-retained, implant-supported crowns and subjected to artificial aging is limited.

PURPOSE: The purpose of this in vitro study was to evaluate the volume loss, maximum wear depth, and fracture resistance of screw-retained implant-supported crowns after thermomechanical aging when fabricated using additively and subtractively manufactured materials.

MATERIAL AND

METHODS

Two additively manufactured composite resins (Crowntec [CT] and VarseoSmile Crown Plus [VS]) and 2 subtractively manufactured materials (1 reinforced composite resin, Brilliant Crios [BC] and 1 polymer-infiltrated ceramic network, Vita Enamic [EN]) were used to fabricate standardized screw-retained, implant-supported crowns. After fabrication, the crowns were cemented on titanium base abutments and then tightened to implants embedded in acrylic resin. A laser scanner with a triangular displacement sensor (LAS-20) was used to digitize the pre-aging state of the crowns. Then, all crowns were subjected to thermomechanical aging (1.2 million cycles under 50 N) and rescanned. A metrology-grade analysis software program (Geomagic Control X 2020.1) was used to superimpose post-aging scans over pre-aging scans to calculate the volume loss (mm3) and maximum wear depth (mm). Finally, all crowns were subjected to a fracture resistance test. Fracture resistance and volume loss were evaluated by using 1-way analysis of variance and Tukey Honestly significant difference (HSD) tests, whereas the Kruskal-Wallis and Dunn tests were used to analyze maximum wear depth. Chi-squared tests were used to evaluate the Weibull modulus and characteristic strength data (α=.05).

RESULTS

Material type affected the tested parameters (P<.001). CT and VS had higher volume loss and maximum wear depth than BC and EN (P<.001). EN had the highest fracture resistance among tested materials (P<.001), whereas BC had higher fracture resistance than CT (P=.011). The differences among tested materials were not significant when the Weibull modulus was considered (P=.199); however, VE had the highest characteristic strength (P<.001).

CONCLUSIONS

Additively manufactured screw-retained, implant-supported crowns had higher volume loss and maximum wear depth. All materials had fracture resistance values higher than the previously reported masticatory forces of the premolar region; however, the higher characteristic strength of the subtractively manufactured polymer-infiltrated ceramic network may indicate its resistance to mechanical complications.

Для цитирования: Diken Türksayar Almira Ada, Demirel Münir, Donmez Mustafa Borga, Olcay Emin Orkun, Eyüboğlu Tan Fırat, Özcan Mutlu. Comparison of wear and fracture resistance of additively and subtractively manufactured screw-retained, implant-supported crowns.. The Journal of prosthetic dentistry. 2023. DOI: 10.1016/j.prosdent.2023.06.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.