MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2018.10.001

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2018

Adjustable-length loop cortical button versus interference screw fixation in quadriceps tendon anterior cruciate ligament reconstruction - A biomechanical in vitro study.

Karkosch Roman Frederik, Ettinger Max, Bachmaier Samuel, Wijdicks Coen A, Smith Tomas

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This biomechanical cadaveric in vitro study aimed to evaluate and compare the dynamic elongation behavior and ultimate failure strength of tibial adjustable-length loop cortical button versus interference screw fixation in quadriceps tendon-based anterior cruciate ligament reconstruction.

METHODS

Sixteen human quadriceps tendons were harvested and fixed into porcine tibiae using either biodegradable interference screw (n = 8) or adjustable loop device (n = 8) fixation. An acrylic block was utilized for femoral adjustable loop device fixation for both groups. All constructs were precycled for 10 times at 0.5 Hz and manually retensioned before tested in position and force control mode each for 1000 cycles at 0.75 Hz according to in vitro loading conditions replicating the in vivo ACL environment. Subsequently, an ultimate failure test at 50 mm/min was performed with mode of failure noted.

FINDINGS: Tibial IS fixation showed no statistically significant differences in the initial (-0.46 vs. -0.47 mm; P = 0.9780), dynamic (2.18 mm vs. 2.89 mm; P = 0,0661), and total elongation (1.72 mm vs. 2.42 mm; P = 0,0997) compared to adjustable loop device fixation. The tibial button fixation revealed an increased ultimate failure load (743.3 N vs. 606.3 N; P = 0.0027), while stiffness was decreased in comparison to screw fixation (133.2 N/mm vs. 153.5 N/mm; P = 0,0045).

INTERPRETATION: Anterior cruciate ligament reconstruction for quadriceps tendon graft using a tibial adjustable-length loop cortical button provides for comparable dynamic stabilization of the knee with increased ultimate failure load at decreased stiffness compared to screw fixation.

Для цитирования: Karkosch Roman Frederik, Ettinger Max, Bachmaier Samuel, Wijdicks Coen A, Smith Tomas. Adjustable-length loop cortical button versus interference screw fixation in quadriceps tendon anterior cruciate ligament reconstruction - A biomechanical in vitro study.. Clinical biomechanics (Bristol, Avon). 2018. DOI: 10.1016/j.clinbiomech.2018.10.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.