MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/00004623-199611000-00010

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 1996

Interobserver reliability and intraobserver reproducibility of the modified Ficat classification system of osteonecrosis of the femoral head.

Smith S W, Meyer R A, Connor P M, Smith S E, Hanley E N

СтатьяПеревод в очереди

Аннотация

Anteroposterior and lateral plain radiographs of 116 osteonecrotic femoral heads were reviewed to assess the interobserver reliability and intraobserver reproducibility of the modified Ficat classification system. The radiographs were reviewed initially and then again six months later by three adult reconstructive surgeons, two general orthopaedic surgeons, two orthopaedic residents, and one musculoskeletal radiologist. All eight observers agreed on the classification of twenty hips (17 per cent) at both the first and the second review of the radiographs. Paired comparisons revealed a mean interobserver kappa reliability coefficient of 0.46 (range, 0.30 to 0.67) for the first review and 0.45 (range, 0.30 to 0.66) for the second. For all observers, the mean rate of perfect agreement between the first and the second review was 68 per cent (range, 56 to 80 per cent). The mean kappa value for intraobserver reproducibility was 0.59 (range, 0.44 [one of the residents] to 0.73 [one of the general orthopaedic surgeons]). No observer or pair of observers had excellent reproducibility or reliability (kappa > 0.75). The poor interobserver reliability and fair intraobserver reproducibility diminishes any meaningful comparison of studies in which the modified Ficat classification system has been used and illuminates the need for a more reliable and reproducible classification system.

Для цитирования: Smith S W, Meyer R A, Connor P M, Smith S E, Hanley E N. Interobserver reliability and intraobserver reproducibility of the modified Ficat classification system of osteonecrosis of the femoral head.. The Journal of bone and joint surgery. American volume. 1996. DOI: 10.2106/00004623-199611000-00010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.