MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fendo.2023.1179521

Медицинская библиотека · Frontiers in endocrinology · 2023

Global biomarkers of oxidative stress and fractures: a matched case-control study.

Yang Shuman, Feng Lijie, Lix Lisa M, Leslie William D, Guo Dingjie, Shi Xianbao, Yuan Baoming

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Evidence for a relationship between oxidative stress and osteoporotic fractures in humans is limited. Fluorescent oxidation products (FlOPs, excitation/emission wavelengths 320/420nm denoted FlOP_320; 360/420nm [FlOP_360]; and 400/475nm [FlOP_400]) are global biomarkers of oxidative stress, and reflect oxidative damage to proteins, phospholipids, and nucleic acids. We investigated the association between FlOPs and a recent osteoporotic fracture.

METHODS

We conducted a case-control study in a Chinese population aged 50 years or older. A recent osteoporotic fracture in the cases was confirmed by x-ray. Cases were matched with community-based non-fracture controls (1:2 ratio) for age (± 4 years) and sex. In addition, we conducted a sensitivity unmatched case-control study which included all fracture cases and all eligible non-fracture controls prior to matching. Plasma FlOPs were measured with a fluorescent microplate reader. We used unconditional logistic regression to analyze the association between FlOPs (per 1-SD increase in logarithmic scale) and fracture; odds ratios (OR) and 95% confidence intervals (95% CI) were reported.

RESULTS

Forty-four cases and 88 matched controls (mean age: 68.2 years) were included. After covariate adjustment (i.e., body mass index, physical activity, and smoking), higher FlOP_360 (OR = 1.85; 95% CI = 1.03 - 3.34) and FlOP_400 (OR = 13.29; 95% CI = 3.48 - 50.69) levels, but not FlOP_320 (OR = 0.56; 95% CI = 0.27 - 1.15), were associated with increased fracture risk. Subgroup analyses by fracture site and unmatched case-control study found comparable associations of FlOP_360 and FlOP_400 with hip and non-hip fractures.

CONCLUSIONS

Higher FlOP_360 and FlOP_400 levels were associated with increased risk of fracture, and this association was comparable for hip and non-hip fractures. Prospective studies are warranted to confirm this finding.

Для цитирования: Yang Shuman, Feng Lijie, Lix Lisa M, Leslie William D, Guo Dingjie, Shi Xianbao, Yuan Baoming. Global biomarkers of oxidative stress and fractures: a matched case-control study.. Frontiers in endocrinology. 2023. DOI: 10.3389/fendo.2023.1179521.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.