MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0167-8140(03)00026-4

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2003

Quality assurance experience with the randomized neuropathic bone pain trial (Trans-Tasman Radiation Oncology Group, 96.05).

Roos Daniel E, Davis Sidney R, Turner Sandra L, O'Brien Peter C, Spry Nigel A, Burmeister Bryan H, Hoskin Peter J, Ball David L

Клиническое исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Trans-Tasman Radiation Oncology Group 96.05 is a prospective randomized controlled trial comparing a single 8 Gy with 20 Gy in five fractions of radiotherapy (RT) for neuropathic pain due to bone metastases. This paper summarizes the quality assurance (QA) activities for the first 234 patients (accrual target 270).

MATERIALS AND

METHODS

Independent audits to assess compliance with eligibility/exclusion criteria and appropriateness of treatment of the index site were conducted after each cohort of approximately 45 consecutive patients. Reported serious adverse events (SAEs) in the form of cord/cauda equina compression or pathological fracture developing at the index site were investigated and presented in batches to the Independent Data Monitoring Committee. Finally, source data verification of the RT prescription page and treatment records was undertaken for each of the first 234 patients to assess compliance with the protocol.

RESULTS

Only one patient was found conclusively not to have genuine neuropathic pain, and there were no detected 'geographical misses' with RT fields. The overall rate of detected infringements for other eligibility criteria over five audits (225 patients) was 8% with a dramatic improvement after the first audit. There has at no stage been a statistically significant difference in SAEs by randomization arm. There was a 22% rate of RT protocol variations involving ten of the 14 contributing centres, although the rate of major dose violations (more than +/-10% from protocol dose) was only 6% with no statistically significant difference by randomization arm (P=0.44).

CONCLUSIONS

QA auditing is an essential but time-consuming component of RT trials, including those assessing palliative endpoints. Our experience confirms that all aspects should commence soon after study activation.

Для цитирования: Roos Daniel E, Davis Sidney R, Turner Sandra L, O'Brien Peter C, Spry Nigel A, Burmeister Bryan H, Hoskin Peter J, Ball David L. Quality assurance experience with the randomized neuropathic bone pain trial (Trans-Tasman Radiation Oncology Group, 96.05).. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2003. DOI: 10.1016/s0167-8140(03)00026-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.