MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-018-3006-x

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2018

Biomechanical and microbiological effects of local vancomycin in anterior cruciate ligament (ACL) reconstruction: a porcine tendon model.

Schüttler Karl-Friedrich, Scharm Alexander, Stein Thomas, Heyse Thomas J, Lohoff Michael, Sommer Frank, Spiess-Naumann Anja, Efe Turgay

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Although there is increasing evidence for the successful use of local vancomycin applied by soaked compresses during ACL reconstruction, there are still little data on its microbiological and biomechanical effects. Furthermore, exact dosage of vancomycin with respect to tendon stability and microbiological effectivity is still unknown.

MATERIALS AND

METHODS

63 porcine flexor digitorum profundus tendons were harvested under sterile conditions from fresh cadaver legs. After contamination with Staphylococcus epidermidis (S. epidermidis), tendons were wrapped into sterile compresses moistened with different concentrations of vancomycin for 10 or 20 min. Sterile sodium chloride was used for control. After treatment, tendons were rolled onto blood-agar plates to test for residual bacterial contamination and tested for maximum load and stiffness using a uniaxial testing device with cryo-clamps for tendon fixation. Agar plates were checked after 1 week of culture at 36 °C for signs of bacterial growth.

RESULTS

When applying vancomycin for only 10 min, bacterial contamination was found in all dosage groups ranging from 28.6% contamination (n = 2 of 7 tendons) when using 10 mg/ml up to 85.7% (n = 6 of 7 tendons) when using 1 mg/ml. Applying vancomycin-soaked compresses for 20 min, bacterial contamination was still found in the groups using 1 mg/ml and 2.5 mg/ml (contamination rate 85.7 and 42.9% respectively). When using 5 mg/ml and 10 mg/ml, no bacterial contamination could be perceived after 7 days of culture. With regard to biomechanical properties, no differences were found regarding maximum load or Young's modulus between groups.

CONCLUSIONS

This study showed no signs of biomechanical impairment of porcine flexor tendons after the use of vancomycin wraps with concentration ranging from 1 to 10 mg/ml for 10 or 20 min at a time zero testing. Contamination with S. epidermidis was cleansed in 100% of tendons when using at least 5 mg/ml of vancomycin for 20 min.

Для цитирования: Schüttler Karl-Friedrich, Scharm Alexander, Stein Thomas, Heyse Thomas J, Lohoff Michael, Sommer Frank, Spiess-Naumann Anja, Efe Turgay. Biomechanical and microbiological effects of local vancomycin in anterior cruciate ligament (ACL) reconstruction: a porcine tendon model.. Archives of orthopaedic and trauma surgery. 2018. DOI: 10.1007/s00402-018-3006-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.