BACKGROUND

Operative treatment of humeral shaft fractures (AO/OTA 12) is being performed more frequently. Accordingly, it is important to understand the complications associated with plate fixation. This study analyzes risk factors associated with mechanical failure following plate fixation of humeral shaft fractures in order to further elucidate the mode and location of failure.

METHODS

A retrospective review of 351 humeral shaft fractures was completed at a single level I trauma center. Eleven of eighty-five humeral shaft fractures had aseptic mechanical failure requiring revision (12.9%), following initial plate fixation. Fracture characteristics (AO type, comminution, location) and fracture fixation (plate type, multiplanar, number of screws proximal and distal to the fracture) were compared between aseptic mechanical failure and those without failure. A forward stepwise logistic regression analysis was performed to determine any significant predictors of aseptic mechanical failure.

RESULTS

There was significant differences in fixation between the aseptic mechanical failure group and those without failure, specifically in the number of screws for proximal fixation (p = 0.008) and distal fixation (p = 0.040). In the aseptic mechanical failure group, patients tended to have less than < 8 cortices of proximal fixation (82%) and less than < 8 cortices of distal fixation (64%). Conversely, in patients without mechanical failure there was a tendency to have greater than > 8 cortices in both the proximal (62%) and distal fixation (70%). A forward stepwise logistic regression analysis found that less than < 8 cortices of proximal fixation was a significant predictor of aseptic failure, OR 7.96 (p = 0.011). We think this can be accounted for due to the variable bone quality, thinner cortices and multiple torsional forces in the proximal shaft that may warrant special consideration for fixation.

CONCLUSION

The current dogma of humeral shaft fracture stabilization is to use a minimum of 3 screws proximal and distal to the fracture, however the current study demonstrates this is associated with higher rates of mechanical failure. In contrast, 4 bicortical screws or more of fixation on either side of the fracture had lower failure rates and may help to reduce the risk of mechanical failure. Level of Evidence Level III.

Для цитирования: Mistry Manisha R, Tat Jimmy, Husain Rafi, Sheth Ujash, Richards Robin R, Nam Diane. Inadequate proximal screw fixation increases risk of failure following plate fixation of diaphyseal humerus fractures.. Journal of orthopaedic surgery and research. 2023. DOI: 10.1186/s13018-023-03566-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.