BACKGROUND

People with metastatic fracture of the humerus are of poor general health. Often they are not able to compensate the handicap of an impaired extremity. Standard osteosynthetic techniques are not always applicable. To reduce the trauma of the operation, we used the Fixion expandable nail system.

METHODS

At two centers, 23 metastatic fractures of the humerus (in 22 patients) were stabilized with a new nailing system. The nail expands under hydraulic pressure up to 150% of its uninflated diameter, gaining long frictional contact to the bone. All patients were followed up until osseous healing occurred or until they died.

RESULTS AND

CONCLUSIONS

The operative time was approximately 32 min, including 1.4 min fluoroscopy time. Nail insertion is brief and therefore not very stressful to the group of debilitated patients who require this intervention. Immediately postoperatively, the upper extremity is stable to permit physiotherapy. In these few patients, we saw no complications. The advantages of the surgical approach appear to outweigh those of conservative management options if a simple and safe surgical technique makes the humerus stable enough to resist normal daily loads.

Для цитирования: Franck W M, Olivieri M, Jannasch O, Hennig F F. An expandable nailing system for the management of pathological humerus fractures.. Archives of orthopaedic and trauma surgery. 2002. DOI: 10.1007/s00402-002-0428-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.