MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jneumeth.2024.110197

Медицинская библиотека · Journal of neuroscience methods · 2024

Development of a novel three-dimensional injection guide for trigeminal ganglia.

Wu Zhouqiang, Zhu Yafen, Xu Lehan, Lai Wenli, Chen Xuepeng, Long Hu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Trigeminal ganglion (TG) plays an important role in the process of orthodontic pain. It's necessary to design an accurate, precise and minimally invasive trigeminal ganglion injection guide plate to study TG.

METHODS

Micro-CT was used to obtain the Dicom format data, and three-dimensional (3D) software (mimics and magics23.03) was used to reconstruct 3D head models. Design and modifications of the TG injection guide plate were performed in Magic 23.03 software, and the guide plate was produced by a 3D stereolithography printer. X-ray, micro-CT, Evans blue, and virus transduction were used to demonstrate the accuracy of the guide-assisted injection. Pain levels were evaluated after using the injection guide by a bite force test and Von Frey test.

RESULTS

X-ray and micro-CT tests confirmed that the injection needle reached the bilateral trigeminal ganglia fossa. The Evans blue test and virus transduction proved that the injected drug could be accurately injected into the bilateral trigeminal ganglion and the lentivirus could be successfully transfected. The percentage of accurate injection was 10/10 (bilateral trigeminal ganglia). Orofacial pain induced by the trigeminal ganglion injection was mild and returned to baseline within seven days.

CONCLUSION

The injection guide described in this study is viable and reliable for the delivery of drugs and virus transduction into the trigeminal ganglia.

Для цитирования: Wu Zhouqiang, Zhu Yafen, Xu Lehan, Lai Wenli, Chen Xuepeng, Long Hu. Development of a novel three-dimensional injection guide for trigeminal ganglia.. Journal of neuroscience methods. 2024. DOI: 10.1016/j.jneumeth.2024.110197.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.