MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.24022

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2018

Contrast-enhanced computed tomography (CECT) attenuation is associated with stiffness of intact knee cartilage.

Nickmanesh Reza, Stewart Rachel C, Snyder Brian D, Grinstaff Mark W, Masri Bassam A, Wilson David R

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Contrast-enhanced computed tomography (CECT) using charged contrast-agents enables quantification of cartilage glycosaminoglycan content. Since glycosaminoglycan content is a key determinant of cartilage compressive stiffness, CECT measurements have the potential to non-invasively assess cartilage stiffness. The objective of this study was to determine whether CECT attenuation, using a cationic contrast-agent (CA4+), correlates with the stiffness of intact cartilage. Six fresh femoral and six fresh tibial compartments with intact cartilage were obtained from patients undergoing total knee replacement surgery. The instantaneous stiffness was determined for 25-50 points on the surface of each compartment using an established indentation technique. The samples were then immersed in CA4+ solution for 48 h, scanned in a micro-CT scanner, and the average CECT attenuation at each indentation site was found for the superficial cartilage. A significant (p < 0.01) and positive correlation was observed between stiffness and CECT attenuation for sites from each individual cartilage surface, with correlation coefficients ranging from r = 0.37-0.57 and r = 0.48-0.69 (p < 0.01) for the tibia and femur, respectively. When data for each type of cartilage surface were pooled together, the correlation coefficients were r = 0.73 for femoral condyle data points and r = 0.49 for tibial plateau data points. CECT provided a map of cartilage stiffness across each surface, which allows regions of low stiffness to be identified. These findings support continued evaluation and development of quantitative imaging techniques to assess the functional properties of cartilage. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2641-2647, 2018.

Для цитирования: Nickmanesh Reza, Stewart Rachel C, Snyder Brian D, Grinstaff Mark W, Masri Bassam A, Wilson David R. Contrast-enhanced computed tomography (CECT) attenuation is associated with stiffness of intact knee cartilage.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2018. DOI: 10.1002/jor.24022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.