m+Medelevator.RU
← Поиск публикаций
Journal of visualized experiments : JoVE · 2025

Biomechanical Effects of Partial Decortication on All-Suture and Conventional Suture Anchors in Different Bone Densities.

СтатьяVideo-Audio MediaПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhu Yiming, Lian Xucan, Jiang Chunyan, Xiao Chi, Zhao Yang

Аннотация

While biomechanical testing has shown a correlation between decortication and anchor failure load, the effects of partial decortication on the biomechanical properties of all-suture anchors remain unclear. We aimed to evaluate the biomechanical effects of partial decortication on all-suture anchors and conventional suture anchors in Sawbones of varying densities. Suture anchors were tested in nondecorticated, partially decorticated, and completely decorticated Sawbones. Two types of all-suture anchors and one type of conventional anchor were evaluated. Two types of biphasic polyurethane foam were used to mimic normal bone: 0.32 g/cm3 density (20 pounds per cubic foot, pcf 20) and osteoporotic bone: 0.16 g/cm3 density (10 pounds per cubic foot, pcf 10). Cyclic loadings were applied, and peak displacement was recorded. After cyclic loading tests, surviving anchors were subjected to pull-to-failure tests. The number of cycles, peak displacement, ultimate failure loads, and failure modes were determined. First, peak displacement was significantly influenced by bone density and anchor type: normal bone models exhibited lower peak displacement than osteoporotic models, and conventional screw-type anchors consistently demonstrated reduced peak displacement compared to all-suture anchors. In contrast, the extent of bone decortication-whether non-decorticated, partially decorticated, or completely decorticated-showed no significant effect on peak displacement. Second, in osteoporotic bone models (10 pounds per cubic foot), no significant difference in failure load was observed between the partially and non-decorticated groups, but both exhibited significantly higher values than the completely decorticated group.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты