MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2017.12.024

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2017

Quasi-static tensile properties of the Cranial Cruciate Ligament (CrCL) in adult cattle: towards the design of a prosthetic CrCL.

Diotalevi Lucien, Petit Yvan, Brailovski Vladimir, Nichols Sylvain, Marchionatti Emma, Wagnac Éric

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Mechanical properties of the Cranial Cruciate Ligament (CrCL) in adult cattle are not well documented and protocols used in the literature focus on testing a full femur-CrCL-tibia complex rather than an isolated CrCL. The aim of this study was to assess a wider range of tensile properties of the CrCL along its anatomic axis with experimental measurements of the global elongation, displacement and strain fields, in order to provide guidelines for the design of CrCL prosthetic surrogates. Fourteen bovine CrCL were harvested from seven mature cows (5.1 ± 1.3 years) weighing 631 ± 90kg. The mean CrCL length was 41.4 ± 1.5mm and its mean cross-section was 103.9 ± 23.8mm2. Pre-conditioning was achieved with 30 cycles of loading from 30 to 200N at a strain rate of 0.02s-1. Specimens were then loaded to failure at the same strain rate. The following results were obtained: the mean ultimate tensile load (UTL) 4372 ± 1485N and the median [quartiles] maximal global elongation 19.3 [17.8; 21.4] %. At first physical signs of tearing, the mean load was 3315 ± 1336N and mean elongation 13.5 ± 4.9%. The mean absorbed energy at failure was 5.23 ± 2.08 MJ.mm-3 and the mean stiffness at various levels of elongation was: 220 ± 195N.%-1 (5%), 285 ± 162N.%-1 (10%), 239 ± 200N.%-1 (15%), 146 ± 59N.%-1 (20%), 153 ± 136N.%-1 (25%). None of these properties were related to the bovine weight, age and side of the body (p > 0.05). An ideal prosthetic surrogate should then follow these sets of properties and the experimental data suggest that the in-vivo maximal elongation is below 13.5%.

Для цитирования: Diotalevi Lucien, Petit Yvan, Brailovski Vladimir, Nichols Sylvain, Marchionatti Emma, Wagnac Éric. Quasi-static tensile properties of the Cranial Cruciate Ligament (CrCL) in adult cattle: towards the design of a prosthetic CrCL.. Journal of the mechanical behavior of biomedical materials. 2017. DOI: 10.1016/j.jmbbm.2017.12.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.