DOI 10.1016/j.injury.2020.05.005
Dynamic limited axial compression yields favorable functional outcomes in the fixation of Pauwels type-3 femoral neck fractures: A retrospective cohort study.
Аннотация
PURPOSE: Pauwels type-3 femoral neck fractures are challenging injuries to manage with high rates of complications after internal fixation and no consensus has been reached regarding the optimal fixation construct. The current study aims to evaluate the effect of dynamic limited axial compression in parallel screws combined with medial buttress plate (SMBP) or lateral compression plate (LCP) fixation of Pauwels type-3 femoral neck fractures.
METHODS
We performed a retrospective analysis of 51 cases of Pauwels type-3 femoral neck fractures who were fixed by SMBP or LCP. Specifically, the screw fixing the femoral head in the buttress plate was omitted. Postoperative complications and functional outcomes were mainly studied.
RESULTS
With a mean follow-up of 19.9 months, the rate of neck shortening was higher in the LCP group than that in SMBP group (32.1% vs. 8.7%, p = 0.04). Neither nonunion nor avascular necrosis was observed in both groups. Good-to-excellent Harris hip score accounts for 95.2% in SMBP group and 89.3% in LCP group (p = 0.40). Moreover, older age, fracture comminution and compression plate fixation predispose to neck shortening.
CONCLUSION
Dynamic limited axial compression by SMBP or LCP fixation was effective to improve the functional outcome of patients with Pauwels type-3 femoral neck fractures.