Dong Zhenxiang, Guo Yihao, Liu Qiang, Zhang Yizhe, Qiu Qianyi, Zhang Xiaodong, Feng Yanqiu
Аннотация
OBJECTIVES: To propose a single repetition time (TR) quantitative magnetic susceptibility imaging method for the lumbar spine using bipolar readout gradient, and compare the quantitative magnetic susceptibility measurement using single TR and dual TR methods for the lumbar spine with different bone densities.
METHODS: A translation correction method was proposed to correct spatial misalignment along the frequency encoding direction between positive and negative gradient readout images, and the phase difference between the images was eliminated using a phase correction method. The data of lumbar vertebrae L1-L5 were collected using single TR and dual TR methods from 6 normal individuals, 2 patients with osteopenia, and 2 patients with osteoporosis. The magnetic susceptibility map was reconstructed, the quantitative results of single TR before and after correction were compared with those of the dual TR method.
RESULTS: The linear regression result of the lumbar spine magnetic susceptibility values obtained by the single TR method before calibration and the dual TR method is Y=0.64*X-11.61. The linear regression result of the lumbar spine magnetic susceptibility values corrected by the single TR method and the dual TR method is Y=1.03*X+0.25. The results of the corrected single TR method were highly consistent with those of the dual TR method, and the calibrated single TR method could effectively distinguish osteopenia and osteoporosis patients from normal individuals.
CONCLUSIONS: The calibrated single TR bipolar readout gradient method can generate artifact-free lumbar spine quantitative magnetic susceptibility distribution maps and reduce data acquisition time by 50%.
METHODS: A translation correction method was proposed to correct spatial misalignment along the frequency encoding direction between positive and negative gradient readout images, and the phase difference between the images was eliminated using a phase correction method. The data of lumbar vertebrae L1-L5 were collected using single TR and dual TR methods from 6 normal individuals, 2 patients with osteopenia, and 2 patients with osteoporosis. The magnetic susceptibility map was reconstructed, the quantitative results of single TR before and after correction were compared with those of the dual TR method.
RESULTS: The linear regression result of the lumbar spine magnetic susceptibility values obtained by the single TR method before calibration and the dual TR method is Y=0.64*X-11.61. The linear regression result of the lumbar spine magnetic susceptibility values corrected by the single TR method and the dual TR method is Y=1.03*X+0.25. The results of the corrected single TR method were highly consistent with those of the dual TR method, and the calibrated single TR method could effectively distinguish osteopenia and osteoporosis patients from normal individuals.
CONCLUSIONS: The calibrated single TR bipolar readout gradient method can generate artifact-free lumbar spine quantitative magnetic susceptibility distribution maps and reduce data acquisition time by 50%.