Microvascular research · 2017
Intra-and inter-observer reliability of nailfold videocapillaroscopy - A possible outcome measure for systemic sclerosis-related microangiopathy.
СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Dinsdale Graham, Moore Tonia, O'Leary Neil, Tresadern Philip, Berks Michael, Roberts Christopher, Manning Joanne, Allen John, Anderson Marina, Cutolo Maurizio, Hesselstrand Roger, Howell Kevin, Pizzorni Carmen, Smith Vanessa, Sulli Alberto, Wildt Marie, Taylor Christopher, Murray Andrea, Herrick Ariane L
Аннотация
OBJECTIVES: Our aim was to assess the reliability of nailfold capillary assessment in terms of image evaluability, image severity grade ('normal', 'early', 'active', 'late'), capillary density, capillary (apex) width, and presence of giant capillaries, and also to gain further insight into differences in these parameters between patients with systemic sclerosis (SSc), patients with primary Raynaud's phenomenon (PRP) and healthy control subjects.
METHODS: Videocapillaroscopy images (magnification 300×) were acquired from all 10 digits from 173 participants: 101 patients with SSc, 22 with PRP and 50 healthy controls. Ten capillaroscopy experts from 7 European centres evaluated the images. Custom image mark-up software allowed extraction of the following outcome measures: overall grade ('normal', 'early', 'active', 'late', 'non-specific', or 'ungradeable'), capillary density (vessels/mm), mean vessel apical width, and presence of giant capillaries.
RESULTS: Observers analysed a median of 129 images each. Evaluability (i.e. the availability of measures) varied across outcome measures (e.g. 73.0% for density and 46.2% for overall grade in patients with SSc). Intra-observer reliability for evaluability was consistently higher than inter- (e.g. for density, intra-class correlation coefficient [ICC] was 0.71 within and 0.14 between observers). Conditional on evaluability, both intra- and inter-observer reliability were high for grade (ICC 0.93 and 0.78 respectively), density (0.91 and 0.64) and width (0.91 and 0.85).
CONCLUSIONS: Evaluability is one of the major challenges in assessing nailfold capillaries. However, when images are evaluable, the high intra- and inter-reliabilities suggest that overall image grade, capillary density and apex width have potential as outcome measures in longitudinal studies.
METHODS: Videocapillaroscopy images (magnification 300×) were acquired from all 10 digits from 173 participants: 101 patients with SSc, 22 with PRP and 50 healthy controls. Ten capillaroscopy experts from 7 European centres evaluated the images. Custom image mark-up software allowed extraction of the following outcome measures: overall grade ('normal', 'early', 'active', 'late', 'non-specific', or 'ungradeable'), capillary density (vessels/mm), mean vessel apical width, and presence of giant capillaries.
RESULTS: Observers analysed a median of 129 images each. Evaluability (i.e. the availability of measures) varied across outcome measures (e.g. 73.0% for density and 46.2% for overall grade in patients with SSc). Intra-observer reliability for evaluability was consistently higher than inter- (e.g. for density, intra-class correlation coefficient [ICC] was 0.71 within and 0.14 between observers). Conditional on evaluability, both intra- and inter-observer reliability were high for grade (ICC 0.93 and 0.78 respectively), density (0.91 and 0.64) and width (0.91 and 0.85).
CONCLUSIONS: Evaluability is one of the major challenges in assessing nailfold capillaries. However, when images are evaluable, the high intra- and inter-reliabilities suggest that overall image grade, capillary density and apex width have potential as outcome measures in longitudinal studies.