MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.23912

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2018

Fibril deformation under load of the rabbit Achilles tendon and medial collateral ligament femoral entheses.

Sevick Johnathan L, Abusara Ziad, Andrews Stephen H, Xu Minjia, Khurshid Saad, Chatha Jansher, Hart David A, Shrive Nigel G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Microscopic visualization under load of the region connecting ligaments/tendons to bone, the enthesis, has been performed previously; however, specific investigation of individual fibril deformation may add insight to such studies. Detailed visualization of fibril deformation would inform on the mechanical strategies employed by this tissue in connecting two mechanically disparate materials. Clinically, an improved understanding of enthesis mechanics may help guide future restorative efforts for torn or injured ligaments/tendons, where the enthesis is often a point of weakness. In this study, a custom ligament/tendon enthesis loading device was designed and built, a unique method of sample preparation was devised, and second harmonic and two-photon fluorescence microscopy were used to capture the fibril-level load response of the rabbit Achilles tendon and medial collateral ligament femoral entheses. A focus was given to investigation of the mechanical problem of fibril embedment. Resultant images indicate a rapid (occurring over approximately 60 μm) change in fibril orientation at the interface of ligament/tendon and calcified fibrocartilage early in the loading regime, before becoming relatively constant. Such a change in fibril angle helps confirm the materially graded region demonstrated by others, while, in this case, providing additional insight into fibril bending. We speculate that the scale of the mechanical problem (i.e., fibril diameters being on the order of 250 nm) allows fibrils to bend over the small (relative to the imaging field of view, but large relative to fibril diameter) distances observed; thus, potentially lessening required embedment lengths. Nevertheless, this behavior merits further investigation to be confirmed. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2506-2515, 2018.

Для цитирования: Sevick Johnathan L, Abusara Ziad, Andrews Stephen H, Xu Minjia, Khurshid Saad, Chatha Jansher, Hart David A, Shrive Nigel G. Fibril deformation under load of the rabbit Achilles tendon and medial collateral ligament femoral entheses.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2018. DOI: 10.1002/jor.23912.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.