MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2309499017730423

Медицинская библиотека · Journal of orthopaedic surgery (Hong Kong) · 2017

Target range of motion at 3 months after arthroscopic rotator cuff repair and its effect on the final outcome.

Tonotsuka Hisahiro, Sugaya Hiroyuki, Takahashi Norimasa, Kawai Nobuaki, Sugiyama Hajime, Marumo Keishi

СтатьяПеревод в очереди

Аннотация

PURPOSE: The postoperative protocol after arthroscopic rotator cuff repair (ARCR) is still controversial. Some surgeons recommend slower rehabilitation in order to improve the integrity of the repair, while others prefer early range-of-motion (ROM) exercise to avoid postoperative stiffness. The purpose of this study was to determine target ROM (T-ROM) measurements at 3 months after ARCR that are predictive of eventual full recovery without structural failure.

METHODS

The cases consisted of 374 shoulders in 360 patients who underwent primary ARCR and were followed up for at least 2 years. Forward flexion (FF) and side-lying external rotation (ER) were measured preoperatively at 3, 6, 9, 12, and 24 months after surgery, and the patients were divided into six subgroups according to the values for each type of ROM at 3 months (ROM-3M). In each subgroup, the final ROM at 24 months after surgery was compared to determine the T-ROM. The average ROMs with time and re-tear rate were then compared between the under-T-ROM and over-T-ROM groups.

RESULTS

The only significant difference in FF was between the 120-129° and 110-119° ROM-3M groups. Therefore, the T-ROM for FF was determined to be 120°. Similarly, the T-ROM for ER was determined to be 20°. Each ROM in the over-T-ROM group was significantly better than that in the under-T-ROM group at all assessments. There was no significant difference in the re-tear rate between the groups.

CONCLUSION

To acquire sufficient ROM in 2 years without high re-tear rate, a target FF of 120° and ER of 20° should be achieved within 3 months after surgery.

Для цитирования: Tonotsuka Hisahiro, Sugaya Hiroyuki, Takahashi Norimasa, Kawai Nobuaki, Sugiyama Hajime, Marumo Keishi. Target range of motion at 3 months after arthroscopic rotator cuff repair and its effect on the final outcome.. Journal of orthopaedic surgery (Hong Kong). 2017. DOI: 10.1177/2309499017730423.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.