MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-014-2471-2

Медицинская библиотека · International orthopaedics · 2014

Is tartrate-resistant acid phosphatase 5b a potent bio-marker for late stage aseptic implant loosening?

Maier Gerrit Steffen, Eberhardt Christian, Strauch Marco, Kafchitsas Konstantinos, Kurth Andreas A

СтатьяПеревод в очереди

Аннотация

PURPOSE: Aseptic loosening is a serious complication after total joint arthroplasty. Plain radiography, along with clinical signs of prosthesis loosening, is the technique of first choice to evaluate loosening of joint replacements. Nevertheless, radiographical signs of osteolysis may not be apparent until progressed stages of loosening. Thus the search for alternative diagnostic methods is of great importance. The purpose of the present study was to evaluate the potential diagnostic significance of TRAP 5b, Osteocalcin, CrossLaps and Bone ALP for aseptic loosening of total joint replacements.

METHODS

Thirty-seven patients (25 women, 12 men, mean age 65 years, age range 54-76 years) treated with revision surgery due to clinically and radiologically confirmed late aseptic prosthesis loosening were examined prospectively. Serum levels of TRAP 5b, Osteocalcin, CrossLaps and Bone ALP were compared with a matched control group (n = 39).

RESULTS

We found a significant decrease in TRAP 5B level in patients with aseptic loosening. Bone ALP and Osteocalcin as markers of osteoblast activity, and CrossLaps as another resorption marker did not allow any prediction of bone remodeling in this late phase of loosening.

CONCLUSION

In the "late" phase of aseptic joint replacement loosening, no increase of TRAP 5b and therefore no increase of osteoclast number and activity was measurable. Thus, in this situation an anti-osteolytic therapy with a bisphosphonate or denosumab would not gain any further benefit.

Для цитирования: Maier Gerrit Steffen, Eberhardt Christian, Strauch Marco, Kafchitsas Konstantinos, Kurth Andreas A. Is tartrate-resistant acid phosphatase 5b a potent bio-marker for late stage aseptic implant loosening?. International orthopaedics. 2014. DOI: 10.1007/s00264-014-2471-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.