DOI 10.1097/jcma.0000000000001112

Медицинская библиотека · Journal of the Chinese Medical Association : JCMA · 2024

Diagnostic ability of macular nerve fiber layer thickness measured by swept-source optical coherence tomography in preperimetric glaucoma.

Yeh Shih-Jung, Su Yi-Wen, Chen Mei-Ju

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

We evaluated the diagnostic ability of macula retinal nerve fiber layer (mRNFL) thickness in preperimetric glaucoma (PPG) patients.

METHODS

This prospective study included 83 patients with PPG and 83 age- and refractive error-matched normal control subjects. PPG was defined as a localized RNFL defect corresponding to glaucomatous optic disc changes with a normal visual field test. We used spectral-domain (SD) optical coherence tomography (OCT) to measure the circumpapillary RNFL (cpRNFL) thickness and macular ganglion cell-inner plexiform layer (GCIPL) thickness. Swept-source (SS) OCT was used to measure cpRNFL thickness, macular ganglion cell layer + inner plexiform layer (IPL) thickness (GCL+), and macular ganglion cell layer + IPL+ mRNFL thickness (GCL++). The mRNFL thickness was defined as GCL++ minus GCL+. To evaluate the diagnostic power of each parameter, the area under the receiver operating characteristics curve (AUROC) was analyzed to differentiate PPG from the normal groups.

RESULTS

Using SD-OCT, all GCIPL parameters and most cpRNFL parameters, except at the nasal and temporal quadrant, were significantly lower in PPG versus normal controls. PPG eyes had significantly smaller values than normal controls for all cpRNFL and GCL parameters measured by SS-OCT, except mRNFL at the superonasal area. The inferotemporal GCL++ had the largest AUROC value (0.904), followed by inferotemporal GCL+ (0.882), inferotemporal GCIPL thickness (0.871), inferior GCL++ (0.866), inferior cpRNFL thickness by SS-OCT (0.846), inferior cpRNFL thickness by SD-OCT (0.841), and inferotemporal mRNFL thickness (0.840). The diagnostic performance was comparable between inferotemporal mRNFL thickness and the best measures of GCL (inferotemporal GCL++, p = 0.098) and cpRNFL (inferior cpRNFL thickness by SS-OCT, p = 0.546).

CONCLUSION

The diagnostic ability of mRNFL thickness was comparable to that of the best measures of cpRNFL and GCL analysis for eyes with PPG. Therefore, mRNFL thickness could be a new parameter to detect early structural changes in PPG.

Для цитирования: Yeh Shih-Jung, Su Yi-Wen, Chen Mei-Ju. Diagnostic ability of macular nerve fiber layer thickness measured by swept-source optical coherence tomography in preperimetric glaucoma.. Journal of the Chinese Medical Association : JCMA. 2024. DOI: 10.1097/jcma.0000000000001112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.