The role of arthroscopy in the treatment of groin pain after total hip arthroplasty: our experience.

Filanti Mattia, Carubbi Chiara, Del Piccolo Nicolandrea, Rani Nicola, Mazzotta Alessandro, Dallari Dante

СтатьяПеревод в очереди

Аннотация

AIM: The purpose of the study was to present our arthroscopic surgical technique and the results in patient with pain after a hip replacement.

METHODS

Between November 2009 and September 2011, 35 patients with groin pain after total hip arthroplasty (THA) were treated arthroscopically. The patients underwent a preoperative examination consisting in careful history, physical examination, laboratory evaluation, diagnostic evaluation using x-rays and pelvis CT scans. In patients for whom the clinical picture suggested iliopsoas tendonitis, we also performed injection of local anaesthetic on the iliopsoas tendon sheath. All the patients were positioned in the supine decubitus position with traction applied, using 2 arthroscopic portals (AL, MID-A). An extensive debridement of adhesions, periprosthetic tissue and neocapsula were performed; when there were signs of iliopsoas impingement, a transcapsular tenotomy was performed according to Wettstein technique.

RESULTS

The average age was 57 (29-77) years old. The average time to onset of symptoms was 10.8 (5-15) months after THA. The average preoperative Harris Hip Score (HHS) was 44.1 (range 32-56). The average preoperative Medical Research Council (MRC) scale for muscle strenght was 3.27 (range 3-4). After 24 months of follow-up patients show an average HHS of 75.73 (range 50-91). Patients who underwent iliopsoas release show a postoperative HHS of 83.28 (range 61-91). The average postoperative MRC scale was 4.45.

CONCLUSIONS

Hip arthroscopy in treatment of reactive synovitis and adhesions shows good results according to literature. Hip arthroscopy in treatment of anterior iliopsoas impingement is the most useful instrument, being less invasive than the classic open technique.

Для цитирования: Filanti Mattia, Carubbi Chiara, Del Piccolo Nicolandrea, Rani Nicola, Mazzotta Alessandro, Dallari Dante. The role of arthroscopy in the treatment of groin pain after total hip arthroplasty: our experience.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2016. DOI: 10.5301/hipint.5000405.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.