DOI 10.3389/fdgth.2023.1223845
Comparison of machine learning approaches for near-fall-detection with motion sensors.
Аннотация
INTRODUCTION
Falls are one of the most common causes of emergency hospital visits in older people. Early recognition of an increased fall risk, which can be indicated by the occurrence of near-falls, is important to initiate interventions.
METHODS
In a study with 87 subjects we simulated near-fall events on a perturbation treadmill and recorded them with inertial measurement units (IMU) at seven different positions. We investigated different machine learning models for the near-fall detection including support vector machines, AdaBoost, convolutional neural networks, and bidirectional long short-term memory networks. Additionally, we analyzed the influence of the sensor position on the classification results.
RESULTS
The best results showed a DeepConvLSTM with an F1 score of 0.954 (precision 0.969, recall 0.942) at the sensor position "left wrist."
DISCUSSION: Since these results were obtained in the laboratory, the next step is to evaluate the suitability of the classifiers in the field.