MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-023-05038-7

Медицинская библиотека · Clinical oral investigations · 2023

In vitro fatigue and fracture testing of temporary materials from different manufacturing processes in implant-supported anterior crowns.

Bein Laila, Rauch Angelika, Schmidt Michael, Rosentritt Martin

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to investigate the in vitro fatigue and fracture force of temporary implant-supported anterior crowns made of different materials with different abutment total occlusal convergence (TOC), with/without a screw channel, and with different types of fabrication.

MATERIALS AND

METHODS

One hundred ninety-two implant-supported crowns were manufactured (4° or 8° TOC; with/without screw channel) form 6 materials (n = 8; 2 × additive, 3 × subtractive, 1 × automix; reference). Crowns were temporarily cemented, screw channels were closed (polytetrafluoroethylene, resin composite), and crowns were stored in water (37 °C; 10 days) before thermal cycling and mechanical loading (TCML). Fracture force was determined.

STATISTICS: Kolmogorov-Smirnov, ANOVA; Bonferroni; Kaplan-Meier; log-rank; α = 0.05.

RESULTS

Failure during TCML varied between 0 failures and total failure. Mean survival was between 1.8 × 105 and 4.8 × 105 cycles. The highest impact on survival presented the material (η2 = 0.072, p < .001). Fracture forces varied between 265.7 and 628.6 N. The highest impact on force was found for the material (η2 = 0.084, p < .001).

CONCLUSION

Additively and subtractively manufactured crowns provided similar or higher survival rates and fracture forces compared to automix crowns. The choice of material is decisive for the survival and fracture force. The fabrication is not crucial. A smaller TOC led to higher fracture force. Manually inserted screw channels had negative effects on fatigue testing.

CLINICAL RELEVANCE: The highest stability has been shown for crowns with a low TOC, which are manufactured additively and subtractively. In automix-fabricated crowns, manually inserted screw channels have negative effects.

Для цитирования: Bein Laila, Rauch Angelika, Schmidt Michael, Rosentritt Martin. In vitro fatigue and fracture testing of temporary materials from different manufacturing processes in implant-supported anterior crowns.. Clinical oral investigations. 2023. DOI: 10.1007/s00784-023-05038-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.