Stress intensity factor of a cracked molar restored with different materials and designs: A 3D-FEA.

Jiang Jingang, Sun Jianpeng, Ma Hongyuan, Wang Jingchao, Huang Zhiyuan, Zhou Shan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

This work used 3D finite element analysis (FEA) to analyze and directly compare the stress intensity factor (SIF) and stress distribution at the crack tip of identical cracked tooth models restored with different materials and crown parameters.

METHODS

A 3D model of the cracked tooth was generated. Then, we applied 25 restorative models, including three parameters (shoulder height, width, and degree of polymerization), five restorative materials (GC, IPS, LU, ZC, VE), and two combinations of types of cement (RMGIC and GIC). An occlusal load of 800N was applied to the spherical part along the longitudinal axis. The stress distribution of the preparation and the SIF of the crack tip was analyzed.

RESULTS

The crack tip SIF was minimal for a shoulder height offset of 0.8 mm (P = 0.032), a shoulder width of 0.6 mm (P = 0.045), a crown material of ZC (P < 2e-16), and a cement material of RMGIC (P < 0.05), respectively. In contrast, the effect of different polymerization degrees on SIF was insignificant (P = 0.95).

CONCLUSION

Our results suggest that the selection of a larger modulus of elasticity (MOE) material for the crown, the preparation of a smaller shoulder width within a safe range, a reasonable increase in the crown length, and the selection of adhesive materials with high fracture toughness are favorable methods to prevent further crack extension.

Для цитирования: Jiang Jingang, Sun Jianpeng, Ma Hongyuan, Wang Jingchao, Huang Zhiyuan, Zhou Shan. Stress intensity factor of a cracked molar restored with different materials and designs: A 3D-FEA.. Journal of the mechanical behavior of biomedical materials. 2023. DOI: 10.1016/j.jmbbm.2023.105818.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.