BACKGROUND

Internal fixation modalities of unstable (>50 percent articular involvement) middle phalangeal volar lip fracture-dislocations include interfragmentary screw and volar buttress plating. This study investigates the mechanical properties (yield strength, ultimate tensile strength, and stiffness) of interfragmentary screw (IS), simple buttress plating (BP) and buttress plating with subchondral screw (BP+S).

METHODS

Fifteen cadaveric digits (5 index, 5 middle, and 5 ring) were prepared by excising its skin envelope and flexor tendons while preserving the structures around the proximal interphalangeal joint. An oblique osteotomy involving 50 percent of the articular surface was performed, and this was fixed with based on its study group: interfragmentary screw (IS), simple buttress plating (BP) and buttress plating with subchondral screw (BP+S). These specimens were then loaded to failure.

RESULTS

Yield strength was as follows: BP+S (33.5±9.76 N), IS (13.6±5.46 N), and BP (8.1±3.84 N). Ultimate tensile strength was as follows: BP+S (49.1±21.4 N), IS (15.6±5.19 N), and BP (8.86±3.99 N). Stiffness was as follows: BP+S (4.77±1.32 N/mm), IS (2.44±0.86 N/mm), and BP (1.84±0.71 N/mm).

CONCLUSIONS

A buttress plate and screw construct confers significantly more stability than either interfragmentary screw or buttress plate only fixation in an experimental model.

Для цитирования: Foo Gen-Lin, Ramruttun Amit K, Cheah Andre Eujin, Chong Alphonsus Kin-Sze, Foo Tun-Lin. Biomechanics of Internal Fixation Modalities for Middle Phalangeal Base Fracture Dislocation.. The journal of hand surgery Asian-Pacific volume. 2017. DOI: 10.1142/s0218810417500022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.