MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0021-9290(02)00061-1

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2002

A biomechanical analysis of the rheumatoid index finger after joint arthroplasty.

Fowler N K, Nicol A C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine the mechanisms responsible for the recurrence of ulnar drift after metacarpophalangeal joint arthroplasty in the rheumatoid hand.

DESIGN

A three-dimensional biomechanical model of the index finger joints was used to predict the implant loads during several activities of daily living.

BACKGROUND

Post-operative clinical evaluation of Sutter metacarpophalangeal prostheses shows a high incidence of fracture and recurrent deformity.

METHODS

A six-component force transducer in conjunction with a six-camera motion analysis system were used to obtain kinematic and external loading data from eight patients with rheumatoid arthritis during several simulated activities. These data were used as input into a three-dimensional biomechanical model of the implant and interphalangeal joints of the index finger. Tendon lines of action and moment arms were obtained using a series of MRI scans and CAD modelling techniques.

RESULTS

Implant forces were oriented in a radial and dorsal direction to resist the ulnarpalmarly pull of tendons associated with the metacarpophalangeal joint.

CONCLUSIONS

The recurrence of ulnar drift is attributable to fatigue failure of the prostheses. After fracture the implant is unable to support the repetitive loading patterns experienced during activities of daily living.

RELEVANCE: Understanding the mechanisms responsible for the recurrence of ulnar drift and implant failure is a step towards improving the prosthesis design, surgical procedures and ultimately the patient's prognosis.

Для цитирования: Fowler N K, Nicol A C. A biomechanical analysis of the rheumatoid index finger after joint arthroplasty.. Clinical biomechanics (Bristol, Avon). 2002. DOI: 10.1016/s0021-9290(02)00061-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.