m+Medelevator.RU
← Поиск публикаций
International endodontic journal · 2023

Comparative analysis of reciprocating and flat-side heat-treated rotary single-file systems: Design, metallurgical characteristics, and mechanical performance.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Martins Jorge N R, Silva Emmanuel J N L, Baruwa Abayomi O, Pereira da Costa Rui, Braz Fernandes Francisco M, Versiani Marco A

Аннотация

AIM: To compare two flat-side single-file rotary instruments with three single-file reciprocating systems through a multimethod assessment.

METHODOLOGY: A total of 290 new NiTi single-file rotary (AF F One Blue 25/0.06 and Platinum V.EU 25/0.06) and reciprocating (One Files Blue R25, Reciproc Blue R25, Reciproc R25) instruments were selected, carefully examined for any major deformations, and evaluated regarding their macroscopic and microscopic design, nickel and titanium elements ratio, phase transformation temperatures, and mechanical performance (time/rotation to fracture, maximum torque, angle of rotation, microhardness, maximum bending, and buckling strengths). One-way anova post hoc Tukey, T-test, and nonparametric Mood's median tests were used for statistical comparisons (α = 5%).

RESULTS: Tested instruments had identical blade counts and near-identical helical angles of approximately 24° (rotary instruments) and 151° (reciprocating instruments). The flat-side analysis revealed a few inconsistencies, such as discontinuity segments, different orientations, and gaps in the homogeneity of the bluish colour. Microscopically, flat-side instruments exhibited blade discontinuity and an incomplete S-shaped cross-section. The surface finish was smoother for One Files Blue and more irregular for both rotary instruments. There were distinct phase transformation temperatures amongst all instruments. All heat-treated instruments were in R-phase arrangement, and Reciproc was in R-phase plus austenite at test temperature (20°C). Compared with the reciprocating instruments, both flat-side instruments exhibited lower results in the cyclic fatigue tests using two different clockwise kinematics, maximum torque, angle of rotation, and maximum buckling strength (p < .05). The rotary systems also exhibited low flexibility (p < .05). AF F One Blue had the lowest microhardness, whilst Reciproc had the highest value.

CONCLUSION: This multimethod investigation revealed that the flat-side rotary instruments underperformed the reciprocating instruments regarding cyclic fatigue (with two different clockwise kinematics), maximum torque, angle of rotation, maximum buckling strength, and flexibility. Manufacturing inconsistencies were also observed in some of the flat-side instruments, including discontinuity segments, different orientations, and in the homogeneity of their bluish colour given by the heat treatment.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты