DOI 10.1016/j.compbiomed.2023.106830

Медицинская библиотека · Computers in biology and medicine · 2023

Computational evaluation of the axis-blade angle for measurements of implant positions in trochanteric hip fractures: A finite element analysis.

Yang Ao-Lei, Mao Wei, Chang Shi-Min, He Yi-Qun, Li Lin-Li, Li Hai-Long, Long Fong, Dong You-Hai

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Recently, a novel approach axis-blade angle (ABA) was developed to measure implant positions during trochanteric hip fracture surgery. It was defined as the sum of two angles α and β measured between the femoral neck axis and helical blade axis in anteroposterior and lateral X-ray films, respectively. Although its clinical practicability has been confirmed, the mechanism is yet to be investigated by means of finite element (FE) analysis.

METHODS

Computed tomography images of four femurs and dimensions of one implant at three angles were obtained to construct FE models. For each femur, 15 FE models in an arrangement (intramedullary nails at three angles multiplying five blade positions) were established. Under the simulation of normal walking loads, the ABA, von Mises stress (VMS), maximum/minimum principal strain and displacement were analyzed.

RESULTS

When the ABA increased, all outcome indicators initially decreased till reaching inferior-middle site and then increased while the blade positions within the femoral head shifted from the superior-anterior quadrant toward the inferior-posterior quadrant, where the ABA were higher. Only the peak VMS of implant models in the inferior-posterior quadrant (particularly the inferior-middle site within) with blades in did not reach the yielding (risky) cut-off.

CONCLUSIONS

From the perspective of angles, ABA, this study demonstrated the inferior-posterior quadrant as the relatively stable and safe regions, especially the inferior-middle site within. This was similar but more elaborate compared with previous studies and clinical practice. Therefore, ABA could be employed as a promising approach to anchor the implants into the optimal region.

Для цитирования: Yang Ao-Lei, Mao Wei, Chang Shi-Min, He Yi-Qun, Li Lin-Li, Li Hai-Long, Long Fong, Dong You-Hai. Computational evaluation of the axis-blade angle for measurements of implant positions in trochanteric hip fractures: A finite element analysis.. Computers in biology and medicine. 2023. DOI: 10.1016/j.compbiomed.2023.106830.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.