MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bpb.0000000000001030

Медицинская библиотека · Journal of pediatric orthopedics. Part B · 2022

Predisposing factors for migration of epiphyseal screws into physis in tension band plating.

Jain Ankit, Agarwal Anil, Jethwa Ravi, Sareen Jatin Raj, Patel Yogesh

СтатьяПеревод в очереди

Аннотация

The migration of epiphyseal screws into growing physis in tension band plating is a known complication. We investigated the screw migration into physis in 10 patients (18 plates) to study the various technical details, which may have contributed to this complication. The methodology involved retrospective review of radiological records. Among these 10 affected patients, in four patients, there were eight additional tension band plates, which had remained uncomplicated ('controls') at the time when implant failure was detected. We statistically compared the length of epiphyseal screw, proximity of screw start point to the physis, screw trajectory angle, interscrew angle and correction rate between the migrated and other uncomplicated plates. Majority patients were postrachitic ( n = 7). The mean time from primary procedure to detection of radiological complication was 15.1 months. The mean epiphyseal screw length proportion in migrated and uncomplicated plates matched. The starting point of epiphyseal screw was relatively closer to physis in migrated plates. The trajectory of epiphyseal screw with respect to physis was more divergent in the migrated plates ( P = 0.02). All implants were inserted in a divergent manner with mean interscrew angle being 22.3° for migrated and 13.8° for the uncomplicated plates ( P = 0.02). The correction rate of the implant reduced as it failed. Osteopenic bone and pathological physis predispose to migrated plates. Technically, a wider trajectory of epiphyseal screw and too divergent screws should be avoided. A migrated implant becomes less effective in its function.

Для цитирования: Jain Ankit, Agarwal Anil, Jethwa Ravi, Sareen Jatin Raj, Patel Yogesh. Predisposing factors for migration of epiphyseal screws into physis in tension band plating.. Journal of pediatric orthopedics. Part B. 2022. DOI: 10.1097/bpb.0000000000001030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.