MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-022-24525-7

Медицинская библиотека · Scientific reports · 2022

Safety and efficacy of two ilioiliac tension band plates osteosynthesis of fragility fractures of the pelvis.

Kułakowski Michał, Reichert Paweł, Elster Karol, Ślęczka Paweł, Oleksy Łukasz, Królikowska Aleksandra

СтатьяПеревод в очереди

Аннотация

The study retrospectively determined the efficacy and safety of fixation of the pelvis (FFP) fragility fractures type IV using two tension band ilioiliac locking compression plates. Forty-one patients with FFP were treated in 2017-2020. 16 patients with FFP type IV, unable to walk weight-bearing, were treated by fixation using two tension band ilioiliac locking compression plates without fixing the anterior ring. Preoperatively and one year postoperatively, the functional outcome and performance were assessed using Pelvic Discomfort Index (PDI) and Timed Up and Go (TUG) test. Pre- and postoperative hemoglobin level was evaluated. Operation time and intra-and postoperative complications were documented. One year postoperatively, an X-ray was taken. The arithmetic mean (x) and standard deviations (±) of quantitative variables were calculated. T-test for dependent samples was used for pre-and postoperative results comparison. The PDI improved (p < 0.001) from x = 81.42 ± 4.04 to x = 36.19 ± 15.58. Preoperatively none of the patients was able to perform the TUG test. Postoperatively, the result exceeded x = 13.13 ± 3.99 s. The operation lasted x = 42.80 ± 8.90 min. Hemoglobin decreased (p < 0.001) from 11.63 ± 1.11 to 9.07 ± 1.21 g/dL. No complications nor fixation loosening were noted. The study support fixation using two tension band ilioiliac locking compression plates as an efficient and safe treatment of the FFP type IV.

Для цитирования: Kułakowski Michał, Reichert Paweł, Elster Karol, Ślęczka Paweł, Oleksy Łukasz, Królikowska Aleksandra. Safety and efficacy of two ilioiliac tension band plates osteosynthesis of fragility fractures of the pelvis.. Scientific reports. 2022. DOI: 10.1038/s41598-022-24525-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.