DOI 10.1080/00365513.2018.1526411

Медицинская библиотека · Scandinavian journal of clinical and laboratory investigation · 2018

Technical and diagnostic performance of a new fully automated immunoassay for the determination of intact fibroblast growth factor 23 (FGF23).

van Helden Josef, Weiskirchen Ralf

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

There is growing interest in measuring plasma fibroblast growth factor 23 (FGF23) concentrations in a number of clinical settings. However, a reliable assay with acceptable performance is lacking. Plasma samples of healthy adults and patients with different stages of chronic kidney disease (CKD) were used to compare the precision, recovery, linearity and the pre-analytical stability characteristics of a new fully automated FGF23 (intact) assay with a commercially available FGF23 (intact) ELISA. Method agreement was evaluated, reference and stage-specific ranges for kidney disease were established. Other biomarkers relevant for CKD were measured and compared with the FGF23 assays. The fully automated FGF23 (intact) assay demonstrated superior performance compared with the ELISA. A marked positive proportional bias was detected relative to the ELISA assay readout, especially in samples of higher concentration of patients undergoing hemodialysis. Overall, the method comparison revealed a poor degree of correlation. A significant inverse correlation was found between the glomerular filtration rate and both FGF23 assays (both p < .001). Regression analysis revealed that both assays are suitable to predict progression of CKD. A positive correlation was found between FGF23 and phosphate, parathyroid hormone (PTH) and vitamin D, 25(OH)D and 1,25(OH)2D-total assays, respectively. Cutoff points between different stages of CKD were calculated by receiver operator characteristic analysis. The fully automated assay displayed an improved discrimination compared with the ELISA, especially in mild to moderate kidney disease. The new fully automated FGF23 (intact) assay demonstrates excellent analytical performance data and represents a robust, fast and precise alternative to manual FGF23 testing.

Для цитирования: van Helden Josef, Weiskirchen Ralf. Technical and diagnostic performance of a new fully automated immunoassay for the determination of intact fibroblast growth factor 23 (FGF23).. Scandinavian journal of clinical and laboratory investigation. 2018. DOI: 10.1080/00365513.2018.1526411.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.