BACKGROUND

Percutaneous vertebroplasty (PVP) has been used widely to treat osteoporotic vertebral compression fractures (OVCFs). However, it has many disadvantages, such as excessive radiation exposure, long operation times, and high cement leakage rates. This study was conducted to explore the clinical effects and safety of the use of a three-dimensional (3D)-printed body-surface guide plate to aid PVP for the treatment of OVCFs.

METHODS

This prospective cohort study was conducted with patients with OVCFs presenting between October 2020 and June 2021. Fifty patients underwent traditional PVP (group T) and 47 patients underwent PVP aided by 3D-printed body-surface guide plates (3D group). The following clinical and adverse events were compared between groups: the puncture positioning, puncture, fluoroscopy exposure and total operation times; changes in vertebral height and the Cobb angle after surgery relative to baseline; preoperative and postoperative visual analog scale and Oswestry disability index scores; and perioperative complications (bone cement leakage, neurological impairment, vertebral infection, and cardiopulmonary complications.

RESULTS

The puncture, adjustment, fluoroscopy, and total operation times were shorter in the 3D group than in group T. Visual analog scale and Oswestry disability index scores improved significantly after surgery, with significant differences between groups (both p < 0.05). At the last follow-up examination, the vertebral midline height and Cobb angle did not differ between groups. The incidence of complications was significantly lower in the 3D group than in group T (p < 0.05).

CONCLUSION

The use of 3D-printed body-surface guide plates can simplify and optimize PVP, shortening the operative time, improving the success rate, reducing surgical complications, and overall improving the safety of PVP.

Для цитирования: Chen Jianquan, Lin Xinyuan, Lv Zhouming, Chen Maoshui, Huang Taosheng. Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures.. PloS one. 2022. DOI: 10.1371/journal.pone.0276930.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.