MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1120700020904933

Медицинская библиотека · Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2020

Tapered, fluted, modular, titanium stems in Vancouver B periprosthetic femoral fractures: an analysis of 87 consecutive revisions.

van Laarhoven Simon N, Vles Georges F, van Haaren Emil H, Schotanus Martijn G M, van Hemert Wouter L W

СтатьяПеревод в очереди

Аннотация

AIMS: One of the instruments in the orthopaedic surgeon's armamentarium to face the challenges associated with periprosthetic fracture around the stem of a hip replacement is the tapered, fluted, modular, titanium (TFMT) stem. Our aim was to study its clinical and radiological outcomes.

PATIENTS AND

METHODS

During the period 2010-2016 86 patients (55 females; median age 78.2 years; mean BMI 26.3 kg/m2; median ASA classification 2) underwent 87 revisions for a Vancouver B periprosthetic fracture using a Stryker Restoration Cone-Conical stem.

RESULTS

After a median follow-up of 2.9 years no stem had to be revised and no case of stem fracture was found. Dislocation was the most common complication and occurred in 18% of patients. Other major complications were deep infection (n = 4), subsidence >5 mm (n = 7), and nonunion (n = 5). 3-month and 1-year mortality was 10% and 15% respectively and was strongly correlated with age, deep infection, and ASA classification. The median EQ-5D health state index at final follow-up was 0.78 and all patients were ambulatory.

CONCLUSIONS

The complication most commonly encountered was dislocation and can likely be prevented by the use of large heads, adequate reduction and fixation of the trochanteric area and restoration of the native anatomy. Contrary to previous concerns, fracture and subsidence of these modular stems do not appear to be a significant problem in this geriatric population.

Для цитирования: van Laarhoven Simon N, Vles Georges F, van Haaren Emil H, Schotanus Martijn G M, van Hemert Wouter L W. Tapered, fluted, modular, titanium stems in Vancouver B periprosthetic femoral fractures: an analysis of 87 consecutive revisions.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2020. DOI: 10.1177/1120700020904933.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.