MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/cid/ciae549

Медицинская библиотека · Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2026

Diagnostic Accuracy of Tuberculosis Screening Tests in a Prospective Multinational Cohort: Chest Radiography With Computer-Aided Detection, Xpert Tuberculosis Host Response, and C-Reactive Protein.

Crowder Rebecca, Thangakunam Balamugesh, Andama Alfred, Christopher Devasahayam J, Dalay Victoria, Nwamba Welile, Kik Sandra V, Van Nguyen Dong, Viet Nhung Nguyen, Phillips Patrick P J, Ruhwald Morten, Theron Grant, Worodria William, Yu Charles, Nahid Payam, Cattamanchi Adithya, Gupta-Wright Ankur, Denkinger Claudia M, R2D2 TB Network

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Accessible, accurate screening tests are necessary to advance tuberculosis case finding and early detection in high-burden countries.

METHODS

We prospectively screened adults with ≥2 weeks of cough at primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. Participants underwent chest radiography, Cepheid Xpert TB Host Response (Xpert HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech). Chest radiographs were processed using CAD4TB v7, a computer-aided detection (CAD) algorithm. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cutoff points were chosen to maximize specificity at 90% sensitivity. Two-test screening algorithms were considered, using (1) sequential negative serial screening (with positive defined as positive on either test) and (2) sequential positive serial screening (with positive defined as positive on both tests).

RESULTS

Between July 2021 and August 2022, a total of 1392 participants with presumptive tuberculosis had valid index tests and reference standard results, and 303 (22%) had confirmed tuberculosis. In head-to-head comparisons, CAD4TB v7 showed the highest specificity at 90% sensitivity (70.3% vs 65.1% for Xpert HR [95% confidence interval for absolute difference in specificity, 1.6%-8.9%] and vs 49.7% for CRP [17.0%-24.3%]). Three 2-test screening algorithms met World Health Organization target product profile minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB (sequential negative), 75.9% for CRP-CAD4TB (sequential negative), and 73.7% for Xpert HR-CAD4TB (sequential positive).

CONCLUSIONS

CAD4TB achieves target product profile targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Clinical Trials Registration. NCT04923958.

Для цитирования: Crowder Rebecca, Thangakunam Balamugesh, Andama Alfred, Christopher Devasahayam J, Dalay Victoria, Nwamba Welile, Kik Sandra V, Van Nguyen Dong, Viet Nhung Nguyen, Phillips Patrick P J, Ruhwald Morten, Theron Grant, Worodria William, Yu Charles, Nahid Payam, Cattamanchi Adithya, Gupta-Wright Ankur, Denkinger Claudia M, R2D2 TB Network. Diagnostic Accuracy of Tuberculosis Screening Tests in a Prospective Multinational Cohort: Chest Radiography With Computer-Aided Detection, Xpert Tuberculosis Host Response, and C-Reactive Protein.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2026. DOI: 10.1093/cid/ciae549.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.