Biomechanical evaluation of the kinematics of the cadaver lumbar spine following disc replacement with the ProDisc-L prosthesis.

Demetropoulos Constantine K, Sengupta Dilip K, Knaub Mark A, Wiater Brett P, Abjornson Celeste, Truumees Eeric, Herkowitz Harry N

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

Biomechanical study of the ProDisc-L in a cadaveric model under pure moment loading. OBJECTIVE.: To determine the kinematic properties of a lumbar spine motion segment and the adjacent level following ProDisc-L disc replacement in the cadaveric spine.

SUMMARY OF BACKGROUND DATA: Total disc replacement is intended to preserve native motion, in an attempt to prevent accelerated adjacent segment degeneration. The quality and quantity of the motion following TDR may have important consequences on the facet joints of the same motion segment, as well as the motion at the prosthetic component interface.

METHODS

Ten cadaveric lumbar spines were radiographed (L3-L5) and tested under pure moments (+10 Nm to -10 Nm) with an applied follower load (200 N). Load-deformation was tested in flexion/extension, lateral bending (LB), and axial rotation (AR). Range of Motion (ROM) data were recorded. Superior adjacent disc pressure (L3-L4) was measured using subminiature pressure transducers. The L4-L5 disc was subsequently instrumented with a ProDisc-L. Radiographs and biomechanical tests were repeated.

RESULTS

Disc replacement significantly reduced extension (ROM 2.2 degrees +/- 0.5 degrees before and 1.2 degrees +/- 0.7 degrees after instrumentation) (P = 0.001), but not flexion (ROM 5.6 degrees +/- 3.1 degrees before and 6.2 degrees +/- 1.2 degrees after) (P = 0.34). Combined flexion/extension motion was marginally reduced (P = 0.517). LB ROM (7.4 degrees +/- 2.0 degrees ) was marginally reduced (P = 0.072) following instrumentation (6.2 degrees +/- 2.5 degrees ), while ROM in AR (3.4 degrees +/- 1.1 degrees ) was significantly increased (4.4 degrees +/- 1.2 degrees ) (P = 0.001). Superior adjacent segment ROM was preserved.No significant differences in disc pressure were observed at the adjacent motion segment before (199 kPa at maximum flexion and 171 kPa at maximum extension) or after disc replacement (252 kPa and 208 kPa, respectively).

CONCLUSION

In cadaveric spines, ROM of operated and adjacent motion segments was preserved following ProDisc-L insertion. Excision of the anterior anulus may increase laxity, which is taken up by the restoration of disc height and lordosis, at the cost of a moderate loss of flexion/extension motion. Adjacent segment kinematics were unaffected following TDR.

Для цитирования: Demetropoulos Constantine K, Sengupta Dilip K, Knaub Mark A, Wiater Brett P, Abjornson Celeste, Truumees Eeric, Herkowitz Harry N. Biomechanical evaluation of the kinematics of the cadaver lumbar spine following disc replacement with the ProDisc-L prosthesis.. Spine. 2010. DOI: 10.1097/brs.0b013e3181c4eb9a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.