MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Pain physician · 2022

Radiation Doses for Different Approaches of Fluoroscopy-Guided Epidural Injections: An Observational Clinical Study.

Sacaklidir Rekib, Ozturk Ekim Can, Sencan Savas, Gunduz Osman Hakan

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Although fluoroscopy-guided interventional therapies have declined in recent years, radiation exposure remains a critical issue for both patients and medical staff. Radiation exposure varies according to the physicians' experience, procedure time, patients' body mass index (BMI), imaging techniques, and the type of procedure performed.

OBJECTIVE

The purpose of this study is to report procedure times and calculate the radiation doses for 4 different approaches of fluoroscopy-guided epidural injections per procedure and BMI to provide radiations doses for potential use in future dose reduction strategies.

STUDY

DESIGN

Retrospective, observational study.

SETTING

A university hospital, pain management center.

METHODS

A retrospective evaluation was performed of patients who received epidural steroid injections between January 2015 and December 2020 in a university hospital interventional pain management center. This observational study was conducted with patients aged >= 18 who underwent 3,711 epidural injections including cervical interlaminar, lumbar interlaminar, lumbar transforaminal, and caudal approaches. If more than one level or bilateral injections were performed, total dose and times were divided by the number of sites injected to attain procedure time and mean dose per injection. Provided doses for each patient were also divided by patients' BMI to obtain dose per BMI.

RESULTS

The highest radiation dose per procedure was found in caudal epidural injection with 0.218 mGy·m2, and the lowest dose was found in cervical interlaminar epidural injection with 0.057 mGy·m2. The radiation dose per procedure was 0.123 mGy·m2 for lumbar transforaminal and 0.191 mGy·m2 for lumbar interlaminar epidural injection. The shortest procedure time was determined in transforaminal (37.3 seconds) injections, and the longest was in lumbar interlaminar (46.7 seconds) injections. Caudal epidural injection also had the highest radiation dose per BMI which was 0.00749, and cervical interlaminar epidural injection had the lowest radiation dose per BMI, which was 0.00214.

LIMITATIONS: Firstly, injections were performed by first- or second-year fellows in pain medicine. Moreover, patient-related factors (previous surgery, scoliosis, etc.) affecting radiation exposure were ignored.

CONCLUSIONS

Radiation dose levels and procedure times of 4 approaches of epidural injections were obtained from 3,711 procedures performed in a university hospital pain medicine clinic. BMI of patients was taken into account with the dose levels of injections given per BMI. Multicenter research with standardized techniques will assure more reliable reference levels, which will guide pain physicians to self-assess their own levels of radiation exposure.

Для цитирования: Sacaklidir Rekib, Ozturk Ekim Can, Sencan Savas, Gunduz Osman Hakan. Radiation Doses for Different Approaches of Fluoroscopy-Guided Epidural Injections: An Observational Clinical Study.. Pain physician. 2022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.