DOI 10.3899/jrheum.140983

Медицинская библиотека · The Journal of rheumatology · 2015

The Longitudinal Reliability and Responsiveness of the OMERACT Hand Osteoarthritis Magnetic Resonance Imaging Scoring System (HOAMRIS).

Haugen Ida K, Eshed Iris, Gandjbakhch Frederique, Foltz Violaine, Østergaard Mikkel, Bøyesen Pernille, Bird Paul, Genant Harry K, Peterfy Charles G, Conaghan Philip G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the interreader reliability of change scores and the responsiveness of the OMERACT Hand Osteoarthritis (OA) Magnetic Resonance Image (MRI) Scoring System (HOAMRIS).

METHODS

Paired MRI (baseline and 5-yr followup) from 20 patients with hand OA were scored with known time sequence by 3 readers according to the HOAMRIS: Synovitis, erosive damage, cysts, osteophytes, cartilage space loss, malalignment, and bone marrow lesions (BML; 0-3 scales with 0.5 increments for synovitis, erosive damage, and BML). Interreader reliability for status and change scores were assessed by intraclass correlation coefficients (ICC), percentage exact agreement and percentage close agreement (PEA/PCA), and smallest detectable change (SDC). Responsiveness was assessed by standardized response means (SRM).

RESULTS

Cross-sectional interreader ICC were good to very good (≥ 0.74) for all features except synovitis, cysts, and malalignment (ICC 0.50-0.58). The range of change values was small, leading to low ICC for change scores. The SDC values for sum scores (total range 0-24) varied between 1.97-3.05 (except 1.08 for malalignment). For status scores, PEA/PCA on scores in individual joints across the readers were 8.1-50.0 and 43.8-78.1, respectively. Similarly, PEA/PCA for change scores were 20.6-63.8 and 66.3-93.1, respectively. All features except cysts and BML demonstrated good responsiveness with higher SRM for sum scores (range 0.46-1.62) than for scores in individual joints (range 0.24-0.73).

CONCLUSION

Good to very good interreader ICC values were found for cross-sectional readings, whereas the longitudinal reliability was lower because of a smaller range of change scores. All features, except cysts and BML, showed good responsiveness.

Для цитирования: Haugen Ida K, Eshed Iris, Gandjbakhch Frederique, Foltz Violaine, Østergaard Mikkel, Bøyesen Pernille, Bird Paul, Genant Harry K, Peterfy Charles G, Conaghan Philip G. The Longitudinal Reliability and Responsiveness of the OMERACT Hand Osteoarthritis Magnetic Resonance Imaging Scoring System (HOAMRIS).. The Journal of rheumatology. 2015. DOI: 10.3899/jrheum.140983.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.