MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12893-022-01813-7

Медицинская библиотека · BMC surgery · 2022

A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection.

Chen Wentao, Wang Baojun, Liu Zhenyu

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Open reduction and internal fixation have been frequently applied for displaced midshaft clavicular fracture. Plate and screw fixation of clavicular fractures could provide rigid fixation and rotational control. Proper implant positioning in surgical fixation is critical to prevent iatrogenic complications. Fluoroscopy plays an important role in the intraoperative evaluation of implants. This study aimed to introduce a new fluoroscopic projection to evaluate the positioning of plates and screws.

METHODS

Adult patients with a diagnosis of acute displaced midshaft clavicular fracture were included in this study. The slope angle of the midshaft clavicle was measured on sagittal reconstructions of preoperative computed tomography (CT) scans. The incidence of screw revision based on intraoperative standard posteroanterior (PA) and PA 25° cephalic skyline projections was compared. The interobserver agreement for the two projections was calculated.

RESULTS

Twenty-nine patients with midshaft clavicular fractures were enrolled from January 2020 to June 2021. The PA 25° skyline projection could clearly display the tangential line of the plate and inferior border of the clavicle. The slope angle on the superior surface of the midshaft clavicle was 26.0 ± 5.8° (range: 18.5-38.3°). The incidence of screw revision using the PA projection (72.4%) was significantly different from that using the PA 25° skyline projection (34.5%) (P < 0.05). The concordance of the screw revision rate based on the standard PA and PA 25° skyline projections was strong, with kappa coefficients of 0.680 (95% CI: 0.394-0.968) and 0.776 (95% CI: 0.537-0.998).

CONCLUSION

The PA 25° skyline projection corresponds to the slope angle of the midshaft clavicle. It can provide more accurate information regarding the proper screw length and be applied as a routine method for intraoperative evaluation.

Для цитирования: Chen Wentao, Wang Baojun, Liu Zhenyu. A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection.. BMC surgery. 2022. DOI: 10.1186/s12893-022-01813-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.