MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-019-03319-z

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2019

Results of plate fixation for humerus fractures in a large single-center cohort.

van de Wall B J M, Ganzert C, Theus C, van Leeuwen R J H, Link B C, Babst R, Beeres Frank J P

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

This study aims to describe the results of plate fixation in one of the largest single-center cohorts that employs plate fixation as the golden standard. Additionally, risk factors related to a negative outcome were identified.

MATERIALS AND

METHODS

This was a retrospective cohort study of all patients treated for a humeral shaft fracture in a level-one trauma center between January 2010 and December 2017 with a mean follow-up of 1 year.

RESULTS

Plate fixation was performed in 102 patients with a humeral shaft fracture. The mean age was 50 (SD 20) years with 54.9% (n = 56) being male. Forty-eight percent (n = 48) had an AO type-A, 34.3% (n = 35) type-B, and 18.7% (n = 19) type-C fracture. Deep surgical site infections and non-union occurred in 1% (n = 1) and 3.9% (n = 4) of patients, respectively. Revision of the implant was performed in 15.7% (n = 16) mainly due to implant-related complaints. Only one patient developed radial nerve palsy after surgery. The median duration to radiological fracture healing and full-weight bearing was 18 (range 7-65) weeks and 14 (range 6-56) weeks, respectively. Risk factors for negative outcome included higher age, osteoporosis, open and higher AO class fractures, performing surgery during out-office hours, and the use of LCP 3.5-mm plate and an anterolateral approach.

CONCLUSION

Plate fixation for humeral shaft fractures has low risks of complications. It should be emphasized that the complications can be further minimized with a greater surgical expertise and by refraining from performing a surgery during out-office hours.

Для цитирования: van de Wall B J M, Ganzert C, Theus C, van Leeuwen R J H, Link B C, Babst R, Beeres Frank J P. Results of plate fixation for humerus fractures in a large single-center cohort.. Archives of orthopaedic and trauma surgery. 2019. DOI: 10.1007/s00402-019-03319-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.