MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14745/ccdr.v49i09a02

Медицинская библиотека · Canada communicable disease report = Releve des maladies transmissibles au Canada · 2023

A Pediatric Investigators Collaborative Network on Infections in Children (PICNIC) multi-centre Canadian descriptive analysis of Haemophilus influenzae bacteremia in children: Emerging serotypes.

Frankel Craig, Robinson Joan, Khan Sarah, Alghounaim Mohammad, McDonald Jane, Lopez Alison, Fanella Sergio, Gunawan John, Wong Jacqueline, Comeau Jeannette, Bowes Jennifer, Slinger Robert, Kalia Angela, Roberts Ashley, Leifso Kirk, Ulanova Marina, Barton Michelle

СтатьяПеревод пока не подготовлен

Аннотация

Among the complications that can occur at dental implants, the fracture of any implant component is a relatively infrequent but clinically relevant problem. Because of their mechanical characteristics, small diameter implants are at higher risk of such complication. The aim of this laboratory and finite element method (FEM) study was to compare the mechanical behavior of a 2.9- and 3.3-mm-diameter implant with a conical connection under standard static and dynamic conditions, following the International Organization for Standardization (ISO) 14801:2017. Finite element analysis was performed to compare the stress distribution on the tested implant systems under a 300-N, 30° inclined force. Static tests were performed with a load cell of 2 kN; the force was applied on the experimental samples at 30° with respect to the implant-abutment axis, with an arm of 5.5 mm. Fatigue tests were performed with decreasing loads, at 2-Hz frequency, until 3 specimens survived without any damage after 2 million cycles. The emergence profile of the abutment resulted the most stressed area in finite element analysis, with a maximum stress of 5829 and 5480 MPa for 2.9- and 3.3-mm-diameter implant complex, respectively. The mean maximum load resulted in 360 N for 2.9-mm-diameter and 370 N for 3.3-mm-diameter implants. The fatigue limit was recorded to be 220 and 240 N, respectively. Despite the more favorable results of 3.3-mm-diameter implants, the difference between the tested implants could be considered clinically negligible. This is probably due to the conical design of the implant-abutment connection, which has been reported to present low stress values in the implant neck region, thus increasing the fracture resistance.

Для цитирования: Frankel Craig, Robinson Joan, Khan Sarah, Alghounaim Mohammad, McDonald Jane, Lopez Alison, Fanella Sergio, Gunawan John, Wong Jacqueline, Comeau Jeannette, Bowes Jennifer, Slinger Robert, Kalia Angela, Roberts Ashley, Leifso Kirk, Ulanova Marina, Barton Michelle. A Pediatric Investigators Collaborative Network on Infections in Children (PICNIC) multi-centre Canadian descriptive analysis of Haemophilus influenzae bacteremia in children: Emerging serotypes.. Canada communicable disease report = Releve des maladies transmissibles au Canada. 2023. DOI: 10.14745/ccdr.v49i09a02.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.