MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5624/isd.20220040

Медицинская библиотека · Imaging science in dentistry · 2022

Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants.

Fontenele Rocharles Cavalcante, Nascimento Eduarda Helena Leandro, Imbelloni-Vasconcelos Ana Catarina, Martins Luciano Augusto Cano, Pontual Andrea Dos Anjos, Ramos-Perez Flávia Maria Moraes, Freitas Deborah Queiroz

СтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images.

MATERIALS AND

METHODS

Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05).

RESULTS

The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values (P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants.

CONCLUSION

The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

Для цитирования: Fontenele Rocharles Cavalcante, Nascimento Eduarda Helena Leandro, Imbelloni-Vasconcelos Ana Catarina, Martins Luciano Augusto Cano, Pontual Andrea Dos Anjos, Ramos-Perez Flávia Maria Moraes, Freitas Deborah Queiroz. Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants.. Imaging science in dentistry. 2022. DOI: 10.5624/isd.20220040.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.