MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0000000000001670

Медицинская библиотека · Journal of orthopaedic trauma · 2020

Impact of Surrounding Canal Size on Time to Union After Intramedullary Nailing of Femur Fractures: Are 10-mm Nails All We Need?

Yoon Richard S, Adams Donald M, Seigerman Daniel A, Lim Philip K, Donegan Derek J, Liporace Frank A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine whether intramedullary nail (IMN) size and its relation to the canal diameter [nail-canal (NC) diameter] impacts the union rate or time to union in the treatment of femoral shaft fractures.

DESIGN

Retrospective review.

SETTING

Two Level 1 and 1 Level 2 trauma centers.

PATIENTS: Two hundred eighty-seven patients met the criteria and were included in the study.

INTERVENTION: Patients were treated with either an antegrade or retrograde IMN. Comparisons were first performed comparing 10- versus 11- versus 13-mm nails. Patients were then divided into 3 groups based on the difference between the size of the femoral canal at the isthmus and the IMN (NC diameter). Group 1: <1.0 mm, group 2: >1.0 and <2.0 mm, and group 3: >2.0 mm.

MAIN OUTCOME MEASUREMENTS: Nonunion rates, mean time to union.

RESULTS

Two hundred eighty-seven patients with a minimum of 12-month follow-up, who were treated with size with IMN for femoral shaft fractures, were assessed for fracture characteristics, time to union, and union rate. When comparing IMN size, no statistical difference was found when comparing time to union or overall union rate. When comparing NC diameter, no significant difference was found in union rate and time to union when comparing between the groups.

CONCLUSION

Similar rate of union and time to union were exhibited regardless of nail size or NC diameter. This can correlate to the standard utilization of a reamed, titanium 10-mm IMN with 5.0-mm interlocking screws in the treatment of femoral shaft fractures, offering potentially less reaming, shorter operative times, and removing unnecessary stock from inventory.

LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Yoon Richard S, Adams Donald M, Seigerman Daniel A, Lim Philip K, Donegan Derek J, Liporace Frank A. Impact of Surrounding Canal Size on Time to Union After Intramedullary Nailing of Femur Fractures: Are 10-mm Nails All We Need?. Journal of orthopaedic trauma. 2020. DOI: 10.1097/bot.0000000000001670.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.