MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3899/jrheum.141199

Медицинская библиотека · The Journal of rheumatology · 2015

Evaluation of Minimally Invasive, Ultrasound-guided Synovial Biopsy Techniques by the OMERACT Filter--Determining Validation Requirements.

Humby Frances, Kelly Stephen, Bugatti Serena, Manzo Antonio, Filer Andrew, Mahto Arti, Fonseca Joao Eurico, Lauwerys Bernard, D'Agostino Maria-Antonietta, Naredo Esperanza, Lories Rik, Montecucco Carlomaurizio, Tak Paul Peter, Fitzgerald Oliver, Smith Malcolm D, Veale Douglas J, Choy Ernest H, Strand Vibeke, Pitzalis Costantino

Оценочное исследованиеСтатьяОбзорВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Because limited data currently support the clinical utility of peripherally expressed biomarkers in guiding treatment decisions for patients with rheumatoid arthritis, the search has turned to the disease tissue. The strategic aim of the Outcome Measures in Rheumatology (OMERACT) synovitis working group over the years has been to develop novel diagnostic and prognostic synovial biomarkers. A critical step in this process is to refine and validate minimally invasive, technically simple, robust techniques to sample synovial tissue, for use both in clinical trials and routine clinical practice. The objective of the synovitis working group (SWG) at OMERACT 12 (2014) was to examine whether recently developed ultrasound (US)-guided synovial biopsy techniques could be validated according to the OMERACT filter for future clinical use recommendation.

METHODS

The SWG examined whether current data reporting US-guided synovial biopsy of both large and small joints addressed the OMERACT filters of truth, discrimination, and feasibility.

RESULTS

There are currently limited data examining the performance of US-guided synovial biopsy, mainly from observational studies. Thus, it remains critical to evaluate its performance, within the clinical trials context, against the current gold standard of arthroscopic biopsy, with particular reference to: (1) synovial tissue yield, (2) capacity to determine treatment response as measured by a validated synovial biomarker, and (3) tolerability of the procedure.

CONCLUSION

We summarize the discrete work packages agreed to as requirements to validate US-guided synovial biopsy and therefore lead to a global consensus on the use of synovial biopsy for research and clinical practice.

Для цитирования: Humby Frances, Kelly Stephen, Bugatti Serena, Manzo Antonio, Filer Andrew, Mahto Arti, Fonseca Joao Eurico, Lauwerys Bernard, D'Agostino Maria-Antonietta, Naredo Esperanza, Lories Rik, Montecucco Carlomaurizio, Tak Paul Peter, Fitzgerald Oliver, Smith Malcolm D, Veale Douglas J, Choy Ernest H, Strand Vibeke, Pitzalis Costantino. Evaluation of Minimally Invasive, Ultrasound-guided Synovial Biopsy Techniques by the OMERACT Filter--Determining Validation Requirements.. The Journal of rheumatology. 2015. DOI: 10.3899/jrheum.141199.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.