DOI 10.1016/j.ijrobp.2008.10.007
Random positional variation among the skull, mandible, and cervical spine with treatment progression during head-and-neck radiotherapy.
Аннотация
PURPOSE: With 54 degrees of freedom from the skull to mandible to C7, ensuring adequate immobilization for head-and-neck radiotherapy (RT) is complex. We quantify variations in skull, mandible, and cervical spine movement between RT sessions.
METHODS AND MATERIALS: Twenty-three sequential head-and-neck RT patients underwent serial computed tomography. Patients underwent planned rescanning at 11, 22, and 33 fractions for a total of 93 scans. Coordinates of multiple bony elements of the skull, mandible, and cervical spine were used to calculate rotational and translational changes of bony anatomy compared with the original planning scan.
RESULTS
Mean translational and rotational variations on rescanning were negligible, but showed a wide range. Changes in scoliosis and lordosis of the cervical spine between fractions showed similar variability. There was no correlation between positional variation and fraction number and no strong correlation with weight loss or skin separation. Semi-independent rotational and translation movement of the skull in relation to the lower cervical spine was shown. Positioning variability measured by means of vector displacement was largest in the mandible and lower cervical spine.
CONCLUSIONS
Although only small overall variations in position between head-and-neck RT sessions exist on average, there is significant random variation in patient positioning of the skull, mandible, and cervical spine elements. Such variation is accentuated in the mandible and lower cervical spine. These random semirigid variations in positioning of the skull and spine point to a need for improved immobilization and/or confirmation of patient positioning in RT of the head and neck.