MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcot.2018.10.016

Медицинская библиотека · Journal of clinical orthopaedics and trauma · 2018

Unreamed Intra-Medullary Nail Versus Half Pin External Fixator in Grade III [A & B] Open tibia fractures.

Garg Sandeep, Khanna Vikram, Goyal M P, Joshi Narendra

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Tibia fracture is the most common long bone fracture. The fractures of tibia are commonly open fractures due to subcutaneous position of the tibia. The choice of technique for stabilization of open tibia fractures includes - External fixation, unreamed intra-medullary nails [URTN], Reamed intra-medullary nails, ORIF with Plating.

OBJECTIVES

To evaluate & compare the results of Unreamed Intra-Medullary Nail Versus Half Pin External Fixator in Grade III [A & B] Open tibia fractures.

METHODS

This prospective clinical study [Randomized chit box] was done on 50 patients presenting to our institute within 24 h of injury. Only those who were skeletally mature with open tibia fracture Grade IIIA & IIIB [Gustilo-Anderson] were included in this study. After initial management, radiological assessment was done. Following this adequate wound debridement, skeletal stabilization with either primary URTN or external fixator was done. Inspection and debridement were repeated at 48-h intervals until the wound was considered clean.

RESULTS

50 cases [25 each group] were compared in terms of - Final Alignment of the Fracture, Presence of Infection/Non-union/Mal-union, Hardware failure, Time to Bone Union, Number of Operative Procedures after index admission. Mean time to full weight bearing was 20.96 weeks in URTN group versus 24.8 weeks in Ex-fix group. 5 in URTN group required further surgery for non-union versus 11 patients in Ex-fix group. There were 6 significant pin track infection. Removal of nail was required in 1 case of deep infection.

CONCLUSION

This study supports the use of the URTN over External fixator in the treatment of severe open tibia fractures.

Для цитирования: Garg Sandeep, Khanna Vikram, Goyal M P, Joshi Narendra. Unreamed Intra-Medullary Nail Versus Half Pin External Fixator in Grade III [A & B] Open tibia fractures.. Journal of clinical orthopaedics and trauma. 2018. DOI: 10.1016/j.jcot.2018.10.016.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.