MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-022-05829-1

Медицинская библиотека · BMC musculoskeletal disorders · 2022

Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: a retrospective analysis of clinical outcomes and radiographic parameters for the gull wing plate.

Mitsuzawa Sadaki, Kusakabe Kenji, Nakao Shota, Matsuoka Tetsuya, Yasuda Tadashi, Matsuda Shuichi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Posterior pelvic ring injuries are challenging for surgeons to treat adequately due to difficulties with reduction and stabilization. Surgical intervention is a beneficial option to protect neurological structures and provide sufficient stability for early mobilization. The gull wing plate (GWP) is a pre-contoured anatomical locking plate with six screws, and its design is unique among posterior transiliac tension-band plates. The purpose of this study was to investigate clinical results of the GWP.

METHODS

Patients who had an unstable posterior pelvic ring injury and underwent internal fixation with GWP were retrospectively analyzed at a trauma center. Demographic data, fracture type, perioperative data, and radiological evaluation with computed tomography (CT) were collected. Clinical outcomes were graded using the functional independence measure (FIM) and Majeed outcome score.

RESULTS

Twenty-six patients were enrolled (mean age, 54 years), and the mean follow-up period was 23 months. The mean Injury Severity Score was 24 points, and internal fixation was performed 6.6 days post-trauma. CT evaluation showed the lateral surface angle of the uninjured ilium was approximately 68°. The GWP pre-contoured anatomical design closely matched this angle. The mean FIM and Majeed score were 119 and 76 points, respectively, which were graded as excellent (n = 14), good (n = 9), or fair (n = 3).

CONCLUSIONS

With the retrospective single-center data available, the GWP seems to be a minimally-invasive alternative, provides reliable stability of the posterior pelvic ring and allows for rehabilitation within normal ranges.

Для цитирования: Mitsuzawa Sadaki, Kusakabe Kenji, Nakao Shota, Matsuoka Tetsuya, Yasuda Tadashi, Matsuda Shuichi. Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: a retrospective analysis of clinical outcomes and radiographic parameters for the gull wing plate.. BMC musculoskeletal disorders. 2022. DOI: 10.1186/s12891-022-05829-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.